50
30.
TROUBLESHOOTING
Problem
Cause
Solution
The stove does not
ignite
Power disconnected\switch off
Protective fuse tripped
Connect the power cable and/or turn on the
switch
Check the fuse located in the switch
It is inside the control board
The stove loads
pellets but there
is no flame
Igniter not working
Brazier clogged with residues
from
combustion.
Brazier inserted incorrectly
Replace the igniter
Empty the brazier and clean it, check and clean
the brazier support and the combustion
chamber
Reposition the brazier
The stove ignites
but during
operation goes
immediately into
modulation
(minimum
power)
Room probe faulty or
regulated with temperature
less than the room
temperature
Remote thermostat (if
connected and set) faulty or
regulated with temperature
less than the room
temperature
Check the probe status or set with a value greater
than the actual room temperature
Check the thermostat operation (if the outdoor
thermostat is the battery powered type, check the
batteries) or set with a value greater than the
actual room temperature
The stove shows
a blackout
No power
Plug improperly connected
Check the connections on both the mains and the
stove, check
(AFTER UNPLUGGING THE POWER
CORD)
proper operation of the switch, hookups,
and terminals
The stove shows
"Smoke
temperature
probe"
Smoke temperature control
probes deteriorated
Contact technical assistance
The stove shows
"Smoke
overheating"
Poor exhaust
The room fan is blocked or
clogged with dust
Check the smoke evacuation airways (flues,
chimneypots)
Check the fan operation, clean any excessive ash
incrustations, and replace if broken.
Contact technical assistance
The stove shows
"Smoke Encoder
faulty"
The control board cannot control
the smoke exhaust speed
Smoke exhaust motor blocked.
Make sure the motor has no mechanical problems
(ash accumulations, bearing partially blocked,
combustion chamber door open), check, clean,
replace
Check the motor, check for any ash accumulations
on the internal impeller
Summary of Contents for DOMUS
Page 6: ...6 FIG 1 ...
Page 30: ...30 PELLET STOVE DOMUS INSTALLATION AND MAINTENANCE MANUAL MOD DOMUS EN ...
Page 45: ...45 ...
Page 55: ...55 ...
Page 56: ...56 POÊLE À GRANULÉS DOMUS GUIDE D INSTALLATION D UTILISATION ET D ENTRETIEN MOD DOMUS FR ...
Page 80: ...80 ...
Page 81: ...81 PELLETKACHEL DOMUS INSTALLATIE GEBRUIKS EN ONDERHOUDSHANDLEIDING MOD DOMUS NL ...
Page 87: ...87 FIG 1 ...
Page 88: ...88 13 TECHNISCHE GEGEVENS ...
Page 100: ...100 ...
Page 109: ...109 ...