CONNECTION TO THE FLUE
(Figura 8)
For the best possible stove functioning, the connection to the flue exhaustion pipe or system must have a positive gradient of no
less than 3% in horizontal pipes. The overall length shall not be more than 2 m whereas, in vertical pipes, between a “T” fitting
and other fittings (change of directions) there must be a distance of minimum 1.5 m and maximum 3 m By using adequate tools,
check that there is a flue draught of at least 12 PA. Allow space for periodic checks and annual cleaning at the lower end of the
flue. Connect the stove to the flue by using adequate pipes and fittings. Make absolutely sure to install an anti-draught chimney in
compliance with current regulations.
21.
CONNECTION TO THE FLUE (Figura 9)
The internal dimensions of the flue must be of maximum 20 x 20 cm, or 20 cm diameter. In case of a bigger flue or bad functioning (cracks,
poor insulation, etc.) insert a stainless steel pipe with adequate diameter, for the entire flue length, from the bottom to the top. By using
adequate tools, check that there is a flue draught of at least 12 PA. Connect the stove to the flue by using adequate pipes and fittings. Make
absolutely sure to install an anti-draught chimney in compliance with current regulations.
22.
USEFUL INFORMATION ABOUT CHIMNEYS
The flue must be compliant with current building regulations. The picture below shows how to connect the fume exhaustion pipe to a pre-
existing flue.
23.
COMMISSIONING
The stove commissioning can only be carried out after installation and assembling. The device must then be connected to the power supply,
water and fume exhaustion system. The stove's finishing varnish dries after the stove has been used for a couple of times. During the first
few days, the device could cause unpleasant smells. Air out the room to get rid of smells. Remove the tools stored in the pellet tank during
packaging. Make sure there is nothing left inside the tank.
24.
FUEL CHARGE
When loading the fuel, make sure the bag containing the pellets doesn't touch the stove.
The fuel has to be loaded in the tank, in the
stove upper area. To load the fuel open up the fuel tank lid, wearing adequate protection gloves to avoid burning your skin when touching
the hot parts in the device. In order to avoid the fire to go out, make sure that the level of pellets inside the tank remains constant. Make
sure that the tank lid is always closed. Only open it when loading the fuel. Be careful not to accidentally insert tools and objects, besides
the fuel, inside the fuel tank.
Fig. 9
Fig. 8
NO
YES
Summary of Contents for DOMUS
Page 6: ...6 FIG 1 ...
Page 30: ...30 PELLET STOVE DOMUS INSTALLATION AND MAINTENANCE MANUAL MOD DOMUS EN ...
Page 45: ...45 ...
Page 55: ...55 ...
Page 56: ...56 POÊLE À GRANULÉS DOMUS GUIDE D INSTALLATION D UTILISATION ET D ENTRETIEN MOD DOMUS FR ...
Page 80: ...80 ...
Page 81: ...81 PELLETKACHEL DOMUS INSTALLATIE GEBRUIKS EN ONDERHOUDSHANDLEIDING MOD DOMUS NL ...
Page 87: ...87 FIG 1 ...
Page 88: ...88 13 TECHNISCHE GEGEVENS ...
Page 100: ...100 ...
Page 109: ...109 ...