          Immediately  upon  receiving  a  fixture,  carefully  unpack  the  carton,  check  the  contents  to 
ensure  that  all  parts  are  present,  and  have  been  received  in  good  condition.  Notify  the  shipper 
immediately  and    retain  packing  material  for  inspection  if  any  parts  appear  damaged  from 
shipping or the carton itself shows sings of mishandling . Save the carton and all packing materials. 
In the event that a fixture must be returned to the factory , it is important that the fixture be returned 
in the original factory box and packing. 

Safety Instructions 

 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user ,be sure 

that they also receive this instruction booklet. 

Always make sure that you are connecting to the proper voltage , and that the line voltage you 

are connecting to is not    higher than that stated on the decal or rear panel of the fixture . 

This product is intended for indoor use only! 
To prevent risk of fire or shock ,do not expose fixture to rain or moisture .Make sure there are 

no flammable materials close to the unit while operating. 

The  unit  must  be  installed  in  a  location  with    adequate  ventilation  ,  at  least    20in  (50cm) 

from adjacent surfaces. Be sure that no ventilation slots are blocked. 

Always disconnect from power source before servicing or replacing fuse and be sure to replace 

with same fuse size and type. 

Secure fixture to fastening device using a safety chain .Never carry the fixture solely by head. 

Use its carrying handles. 

Maximum ambient temperature (Ta) is 104

°

F(40

°

C).Do not operate fixture at temperatures 

higher than this. 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair 

the  unit  by  yourself  .Repairs  carried  out  by  unskilled  people  can  lead  to  damage  or  malfunction. 
Please contact the nearest authorized technical    assistance center .Always use the same type spare 
parts. 

Don’t connect the device to a dimmer pack. 
Make sure    the power cord is never crimped or damaged. 
Never disconnect the power cord by pulling or tugging on the cord. 
Avoid direct eye exposure to the light source while it is on. 
 

Summary of Contents for HS-LMS60R

Page 1: ...1 LED SPOT 60 MOVING HEAD USER MANUAL HS LMS60R ...

Page 2: ...nded for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing fu...

Page 3: ...3 1 SWlTCH ON OFF 2 DMX IN 3 DMX OUT 4 POWR IN 5 MUNE SC 6 UP 7 DOWN 8 ENTER ...

Page 4: ...UND ACTIVED ADDITONAL FEATURES COMPACT LIGHTWEIGHT LED DISPLAY MENU WITH INVERT RESET TO FACTORY SETTING OPTION PAN TILT INVERT OPTION FAN COOLED DMX Channel Summary 13 Channel mode Channel Function CH1 P A N CH2 T I L T CH3 O P E N S H U T T E R CH4 C O L O R W H E E L 7 C O L O R CH5 G O B O W H E E L 7 G O B O CH6 G O B O R O T A T I O N CH7 S P E E D F O R CH8 Dimming CH9 P A N 1 6 B I T CH1 0...

Page 5: ...k Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of digital DMX signal Maximum recommended serial data link distance 500 meters 1640ft Maximum recommended number of fixtures on a serial data link 32 fixtures DMX DATA CABLE Use a Belden 9841 or equivalent cable which meets the specification for EIA RS 485appl...

Page 6: ...output connector you will need to use a 5 pin to 3 pin adapter The chart below details a proper cable conversion 3 OIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5Pin Male Input Ground Shield Pin1 Pin1 Tata signal Pin2 Pin2 Tata signal Pin3 Pin3 Do not use Do not use Do not use Setting up a DMX Serial Date Link 1 Connect the male 3 pin connector side of the DMX cable to the output fem...

Page 7: ...how immediately the first available option for the selected menu function To select a menu item press ENTER Press the MODE ESC button repeatedly until you reach the desired menu function Use the UP and DOWN buttons to navigate the menu options Press the ENTER button to select the menu function currently displayed or to enable a menu option To return to the previous option or menu without changing ...

Page 8: ...8 ...

Page 9: ... 057 075 GOBO 3 076 093 GOBO 4 094 113 GOBO 5 114 132 GOBO 6 133 144 GOBO 7 145 208 WHOLE WHEEL FORWARD F S CH5 GOBO 209 255 WHEEL BACKWARD S F 000 011 NOT ROTATION 012 130 F S CH6 GOBO ROTATION 131 255 S F 000 011 WHITE 012 030 RESET AFTER 10 SECOND 031 250 SHUTTER S F WHITE CH7 STROBOFLASH 251 255 WHITE CH8 DIMMING 000 255 LINEAR DIMMING FROM LIGHT TO DARK CH9 000 255 X 16bit CH10 000 255 Y 16bi...

Page 10: ... size 520x430x420mm Net weight 11 kgs Gross weight 13kgs POWER Powersettings 220V50Hz 60Hz Fuse 2A220V Consumption 150W LIGHT SOURCE 1 X 60W WHITE COLOR LAMP LIFE 50 000Hrs CONTROL PROGRAMMING Data output locking3 pinXLRmalesocket Datainput locking3 pinXLRfemalesocket Protocols DMX 512 DMX channels 13 ...

Reviews: