Returns 

Procedure

The user must send the merchandise prepaid, in the original box, and with its original 
 packing and accessories. We will not issue call tags. 

Call us and request a Return Merchandise Authorization Number (RMA #) before 
shipping the fixture. Be prepared to provide the model number, serial number and 
a brief description of the cause for the return. 

The user must clearly label the package with a Return Merchandise Authorization 
Number (RMA #). We will refuse any product returned without an RMA #. 

DO NO T write t he RMA # directly on t he b ox. Instead, write it o n a properly 
affixed label. 

Claims

For other issues such as missing components or parts, damage not related to shipping, 
or concealed damage, the customer must make claims to us within seven (7) days of
receiving the merchandise. 

Once you are given an RMA #, please include the following information on a piece of 
paper inside the box: 
•     Your name 
•     Your address 
•     Your phone number 
•     The RMA # 
•     A brief description of the symptoms 

 

Be sure to pack the fixture properly. Any shipping damage resulting from inadequate 
packaging will be the customer's responsibility. As a suggestion, proper UPS packing 
or double-boxing is always a safe method to use. 

We reserves the right t o u se it s own discretion t o repair o r replace returned 
product(s). 

The carrier is responsible for any damage incurred during shipping. Therefore, if the 
received merchandise appears to have damages caused during shipping, the customer 
must submit the damage report and any related claims with the carrier, not ours. 
The customer must submit the report upon reception of the damaged merchandise.
 Failure to do so in a timely manner may invalidate the customer's claim 
with the carrier. 

--19--

 

Technical Specifications

Weight & Dimensions  
Length................................................................................................................................. 11.4 in (290 mm) 
Width .................................................................................................................................. 11.6 in (295 mm) 
Height ................................................................................................................................. 19.1 in (485 mm) 
Weight ................................................................................................................................... 30 l bs (13.6 kg) 

 

Power  
Auto-ranging ................................................................................................................. 100~ 240 V, 50/60 Hz 
Power Consumption @ 120 V, 60 Hz .............................................. 150 W , 1.2 A (operation), 0.1 A (inrush) 
Power Consumption @ 240 V, 50 Hz .............................................. 145 W , 0.6 A (operation), 0.1 A (inrush) 

 

Light Source  
LED ................................................................................................ ................................. 60 W, 50,000 hours 
Quantity ........................................................................................................................................................ 1 

 

Photo Optic  
Luminance at 2 m ............................................................................................................................ 5,400 l ux 
Beam angle .............................................................................................................................................. 15° 

 

Control & Programming

 

Data input ...................................................................................................... locking 3-pin XLR male socket 
Data output ................................................................................................. l ocking 3-pin XLR female socket 
Data pin configuration .................................................................................... pi n 1 shield, pin 2 (-), pin 3 (+) 
Protocols............................................................................................................................ USITT DMX512-A  
DMX Channels ............................................................................................................................... 11 and 14  

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for MH LED 60D

Page 1: ...User Manual LED MOVING HEAD MH LED 60D Please Read over this Manual before Operating the Light Fixture...

Page 2: ...aster Slave Linking 6 Mounting 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Description 8 Control Options 8 Programming 8 DMX Operation 8 Stand alone Operation 8 Master Slave Operation 8 Disp...

Page 3: ...ixtures 22 DMX Data Cabling 22 Making your Own DMX Cable 22 DMX Cable Characteristics 22 DMX Cable Connectors 23 3 Pin to 5 Pin Conversion Chart 23 DMX Connection 23 Master Slave Linking 24 Master Sla...

Page 4: ...con indicates useful although non critical information This icon indicates important installation or configuration in formation Failure to comply with this information may prevent the fixture from fun...

Page 5: ...n or moisture Make sure there are no flammable materials close to the fixture s while operating When hanging this fixture always secure it to a fastening device using a safety cable not provided Alway...

Page 6: ...olor Wheel Tilt Fine 4 Fixed Gobo Wheel 1 Pan Tilt Speed 5 Rotating Gobo Wheel 2 Color Wheel 6 Gobo Rotation Fixed Gobo Wheel 1 7 Rotating Prism Rotating Gobo Wheel 2 8 Focus Gobo Rotation 9 Dimmer Ro...

Page 7: ...Product Dimensions Drawing Here Base Fan Fuse Holder Control Panel Base Fan DMX Out DMX In Power Input On Off Switch 4...

Page 8: ...draw during normal operation Please refer to the Sizing the Circuit B reakers section in the Appendix chapter of this manual Never c onnect the light to a r heostat variable r esistor or dimmer circu...

Page 9: ...X controller in a master slave operating mode If you are not familiar with the DMX standard please refer to the DMX Primer and DMX Connectivity sections in the Appendix chapter of this manual The ligh...

Page 10: ...ion programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilationmay affect it Make sure that the loc...

Page 11: ...hange levels in the Menu M ap This is equivalent to move right and left respectively Use UP and DOWN to move vertically within theMenu Map options 1 Select DMX operation a Go to MENU INTRO RUN b Selec...

Page 12: ...ue 000 255 7 Go to MENU EDIT XY SPEED 8 Select a tilt pan movement speed 000 255 9 Go to MENU EDIT COLOR 10 Select a color wheel position 000 255 as per the DMX Values table 11 Go to MENU EDIT GOBO 1...

Page 13: ...E T FINISH 8 Select the finishing point for the limited tilt 000 255 9 Go to MENU RANGE USE 10 Select YES to activate the new settings or NO to stop using them 1 Go to MENU SPECIAL BLACK 2 Select YES...

Page 14: ...11...

Page 15: ...8 Gobo 9 Shaking gobo 9 Shaking gobo 8 Shaking gobo 7 Shaking gobo 6 Shaking gobo 5 Shaking gobo 4 Shaking gobo 3 Shaking gobo 2 Shaking gobo 1 Flow effect 000 009 010 019 020 029 030 039 040 049 050...

Page 16: ...stom Test 3 s delay No function Reset 3 s delay No function 000 255 0 540 000 255 0 270 000 016 017 033 034 050 051 067 068 084 085 101 102 118 119 135 136 152 153 255 White Red Yellow Magenta Green O...

Page 17: ...sm engaged no rotation CCW rotation Slow Fast No function CW rotation Slow Fast 000 255 000 255 Dark Bright 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Close Open Strobe Slow Fast...

Page 18: ...lass cleaning fluid Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable intern...

Page 19: ...eplace optical sensor Faulty X Y control board Circuit breaker fuse keeps tripping blowing Excessive circuit load Check total load placed on the electrical circuit Short circuit along the power wires...

Page 20: ...Exploded View 17...

Page 21: ...175 Q260LED Right base cover P300 Q260BB 3 pin XLR A socket P135 XLRA 3 pin XLR B socket P135 XLRB IEC power input and fuse socket P190 Q260LED On Off switch P100 SWTCH Fixed gobo wheel P169 Q260LEDS...

Page 22: ...equate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use We reserves the right t o u se it s own discretion t o repair...

Page 23: ...nalities The DMX fixture configuration consists in determining how many channels each fixture will need as well as assigning the corresponding DMX channels to each fixture in order to size correctly t...

Page 24: ...The order in which the fixtures connect to the DMX controller is not important and it has no effect on how a controller communicates to each fixture However the user should always define a physical lo...

Page 25: ...he chassis ground a ground l oop could form which may cause the fixture to perform erratically If you use a DMX controller or fixture with a 5 pin DMX connector you will need to use a 5 pin to 3 pin a...

Page 26: ...ave mode Make sure the fixtures with which you are working are capable of operating in Master Slave mode When working in Master Slave mode most fixtures use the DMX data connection as well The differe...

Page 27: ...nd a unique ID address for each fixture This allows the user to control simultaneously the whole group of units at that DMX address by setting the ID Addressing channel to 0 Similarly the user can con...

Page 28: ...y be too low with respect to the actual current drawn by the fixture In fact as the PF decreases the difference between the current calculated using the watts volts method and the actual current incre...