background image

Safety

Notes

Operation 

Expected LED 

Lifespan

Please  read  the  following  notes  carefully  because  they  include  important  
safety information about the installation, usage and maintenance of this product.
It is important to read all these notes before starting to work with this product.

There are no user serviceable parts inside the light. Any reference to servicing this unit 
you may find from now on in this User Manual will only apply to properly C we certified 
technicians. Do not o pen the housing or attempt any repairs unless you are one of them. 

Please refer to all applicable local codes and regulations for proper installation 
of the light. 

Keep this manual for future consultation. If you sell the light  to another user, make 
sure that they also receive this manual. 

Personal 
     Safety 

     Mounting 
and Rigging

          

 

Power 

 and Wiring 

 Avoid direct eye exposure to the light source while the fixture is on. 
 Always disconnect the light  from its power source before servicing. 
 Always connect the light  to a grounded circuit to avoid the risk of electrocution. 

 

 This product is for indoor use only! To prevent risk of fire or shock, do not expose 

    

this product to rain or moisture. 

 Make sure there are no flammable materials close to the fixture(s) while operating. 
 When hanging this fixture, always secure it to a fastening device using a safety

   

 cable (not provided). 

 Always make sure that you are connecting the light  to the proper voltage, as per the 

specifications in this manual or on the product's sticker. 

 Never connect the light to a dimmer pack. 
 Make sure that the power cable is not cracked, crimped or damaged. 
 Never disconnect the fixture by pulling or tugging on the power cable. 

 The maximum ambient temperature (Ta) is 104  F (40

 C). Do not operate the 

     fixture at a higher temperature. 

 In case of a serious operating problem, stop using this product immediately! 

In t he unlikely e vent t hat your light may require ser vice, please contact our Technical 
Support. 

LEDs gradually decline in brightness over time, mostly because of heat. Packaged in 
clusters, LEDs exhibit higher operating temperatures than in ideal or singular optimum 
conditions. For this reason, using all color .LEDs at their fullest intensity significantly 
reduces the LEDs' lifespan. Under normal conditions, this lifespan can be of 40,000 to 
50,000 hours. If extending this lifespan expectancy is vital, lower the operational 
temperature by improving ventilation and reducing the external temperature , as well 
as limiting the overall projection intensity 

--2--

Summary of Contents for MH LED 60D

Page 1: ...User Manual LED MOVING HEAD MH LED 60D Please Read over this Manual before Operating the Light Fixture...

Page 2: ...aster Slave Linking 6 Mounting 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Description 8 Control Options 8 Programming 8 DMX Operation 8 Stand alone Operation 8 Master Slave Operation 8 Disp...

Page 3: ...ixtures 22 DMX Data Cabling 22 Making your Own DMX Cable 22 DMX Cable Characteristics 22 DMX Cable Connectors 23 3 Pin to 5 Pin Conversion Chart 23 DMX Connection 23 Master Slave Linking 24 Master Sla...

Page 4: ...con indicates useful although non critical information This icon indicates important installation or configuration in formation Failure to comply with this information may prevent the fixture from fun...

Page 5: ...n or moisture Make sure there are no flammable materials close to the fixture s while operating When hanging this fixture always secure it to a fastening device using a safety cable not provided Alway...

Page 6: ...olor Wheel Tilt Fine 4 Fixed Gobo Wheel 1 Pan Tilt Speed 5 Rotating Gobo Wheel 2 Color Wheel 6 Gobo Rotation Fixed Gobo Wheel 1 7 Rotating Prism Rotating Gobo Wheel 2 8 Focus Gobo Rotation 9 Dimmer Ro...

Page 7: ...Product Dimensions Drawing Here Base Fan Fuse Holder Control Panel Base Fan DMX Out DMX In Power Input On Off Switch 4...

Page 8: ...draw during normal operation Please refer to the Sizing the Circuit B reakers section in the Appendix chapter of this manual Never c onnect the light to a r heostat variable r esistor or dimmer circu...

Page 9: ...X controller in a master slave operating mode If you are not familiar with the DMX standard please refer to the DMX Primer and DMX Connectivity sections in the Appendix chapter of this manual The ligh...

Page 10: ...ion programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilationmay affect it Make sure that the loc...

Page 11: ...hange levels in the Menu M ap This is equivalent to move right and left respectively Use UP and DOWN to move vertically within theMenu Map options 1 Select DMX operation a Go to MENU INTRO RUN b Selec...

Page 12: ...ue 000 255 7 Go to MENU EDIT XY SPEED 8 Select a tilt pan movement speed 000 255 9 Go to MENU EDIT COLOR 10 Select a color wheel position 000 255 as per the DMX Values table 11 Go to MENU EDIT GOBO 1...

Page 13: ...E T FINISH 8 Select the finishing point for the limited tilt 000 255 9 Go to MENU RANGE USE 10 Select YES to activate the new settings or NO to stop using them 1 Go to MENU SPECIAL BLACK 2 Select YES...

Page 14: ...11...

Page 15: ...8 Gobo 9 Shaking gobo 9 Shaking gobo 8 Shaking gobo 7 Shaking gobo 6 Shaking gobo 5 Shaking gobo 4 Shaking gobo 3 Shaking gobo 2 Shaking gobo 1 Flow effect 000 009 010 019 020 029 030 039 040 049 050...

Page 16: ...stom Test 3 s delay No function Reset 3 s delay No function 000 255 0 540 000 255 0 270 000 016 017 033 034 050 051 067 068 084 085 101 102 118 119 135 136 152 153 255 White Red Yellow Magenta Green O...

Page 17: ...sm engaged no rotation CCW rotation Slow Fast No function CW rotation Slow Fast 000 255 000 255 Dark Bright 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 Close Open Strobe Slow Fast...

Page 18: ...lass cleaning fluid Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable intern...

Page 19: ...eplace optical sensor Faulty X Y control board Circuit breaker fuse keeps tripping blowing Excessive circuit load Check total load placed on the electrical circuit Short circuit along the power wires...

Page 20: ...Exploded View 17...

Page 21: ...175 Q260LED Right base cover P300 Q260BB 3 pin XLR A socket P135 XLRA 3 pin XLR B socket P135 XLRB IEC power input and fuse socket P190 Q260LED On Off switch P100 SWTCH Fixed gobo wheel P169 Q260LEDS...

Page 22: ...equate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use We reserves the right t o u se it s own discretion t o repair...

Page 23: ...nalities The DMX fixture configuration consists in determining how many channels each fixture will need as well as assigning the corresponding DMX channels to each fixture in order to size correctly t...

Page 24: ...The order in which the fixtures connect to the DMX controller is not important and it has no effect on how a controller communicates to each fixture However the user should always define a physical lo...

Page 25: ...he chassis ground a ground l oop could form which may cause the fixture to perform erratically If you use a DMX controller or fixture with a 5 pin DMX connector you will need to use a 5 pin to 3 pin a...

Page 26: ...ave mode Make sure the fixtures with which you are working are capable of operating in Master Slave mode When working in Master Slave mode most fixtures use the DMX data connection as well The differe...

Page 27: ...nd a unique ID address for each fixture This allows the user to control simultaneously the whole group of units at that DMX address by setting the ID Addressing channel to 0 Similarly the user can con...

Page 28: ...y be too low with respect to the actual current drawn by the fixture In fact as the PF decreases the difference between the current calculated using the watts volts method and the actual current incre...

Reviews: