background image

 

 

14 

User Configurations 

 

TO SET THE PAN TO INVERTING OR NON- INVERTING: 

 

1) Press the Mode button until it shows

or 

 

2) Use the Up/Down buttons to set to the desired 

inversion, press enter to confirm.

 

TO SET THE TILT TO INVERTING OR NON- INVERTING:

 

1) Press the Mode button until it shows 

or 

 

  2) Use the Up/Down buttons to set to the desired 

inversion, press enter to confirm.

 

TO SET THE LED READOUT TO INVERTING OR NON- 

INVERTING: 

 

1) Press the Mode button until it shows 

or 

 

2) Use the Up/Down buttons to set to the 
desired inversion, press enter to confirm.

 

TO SET THE DMX CHANNEL CONFIGURATION: 

 

1) Press the Mode button until it shows 

1

2

C

H

 

2) Use the Up/Down buttons to set to the desired 

inversion, press enter to confirm.

 

 

 

 

Fixture Linking 

You will need a serial data link to run light shows of one or more 

fixtures using a DMX-512 controller or to run synchronized shows 

on two or more fixtures set to a master/slave operating mode. The 

combined number of channels required by all the fixtures on a serial 

data link determines the number of fixtures the data link can support.

 

Important:   

Fixtures on a serial data link must be 

daisy chained in one single line. To 

comply with the EIA-485                                                                     

standard no more than 32 devices should 

be connected on one data link. 

Connecting more than 32                                                                       

fixtures on one serial data link without 

the use of a DMX optically-isolated 

splitter may result in

 

deterioration of the digital DMX signal.

 

Maximum recommended serial 

data link distance: 500 meters 

(1640 ft.) Maximum 

recommended number of fixtures 

on a serial data link: 32 fixtures 

Summary of Contents for MINI WASH MOVING HEAD

Page 1: ...1 MINI WASH MOVING HEAD USER MANUAL Suitable for 1w or 3w mode...

Page 2: ...ling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power...

Page 3: ...ll fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 sw...

Page 4: ...1 Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units Proper performance it may be necessary to use a terminator at the last fixture For more info...

Page 5: ...display reads slow Master Slave Mode Master Sound This mode will allow you to link up to 32 units together without a controller 5 Compact and lightweight LED display menu with invert Reset to factory...

Page 6: ...MUM PAN ANGLE 1 Press the Mode button until it shows or or 2 Use the Up Down buttons to set to the desired inversion press enter to confirm TO SET THE MA X I MUM TILT ANGLE 1 Press the Mode button unt...

Page 7: ...nversion press enter to confirm 7 Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fix...

Page 8: ...he cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximu...

Page 9: ...that follow may also require a slave setting Please consult the Operating Instructions section in this manual for complete instructions for this type of setup and configuration 9 DMX connector configu...

Page 10: ...er 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to...

Reviews: