2
ENGLISH
IMPORTANT
1. This booklet is an integral and essential
part of the product and should be kept and
preserved by the user. Please read carefully
the guidelines and warnings contained herein
as they are intended to provide the user
with essential information for the continued
safe use and maintenance of the product. In
addition, it provides GUIDANCE ONLY to the
user on the correct services and site location
of the ice dispenser. Please preserve this
booklet for any further consultation that may
be necessary.
2. This is a commercial ice dispenser, and
should be destined only to be used
for the purpose for which it has been
expressly designed. Any other use should
be considered improper and therefore
dangerous. The manufacturer will not be held
liable or responsible for any damage caused
by improper, incorrect and unreasonable use.
I. Installation Instructions
WARNING
The installation must be carried out by
qualified personnel, in accordance with current
regulations, according to the manufacturer’s
instructions.
1. Location
IMPORTANT
1. This ice dispenser is not intended for outdoor
use. Normal operating ambient temperature
should be 7°C to +38°C. Normal
operating water temperature should be
7°C to +32°C. Operation of the ice
dispenser, for extended periods, outside of
these normal temperature ranges may affect
production capacity.
2. The ice dispenser should not be located next
to ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment at normal
counter top height.
4. Allow 15 cm clearance at rear, sides, and
top for proper air circulation and ease of
maintenance and/or service should they be
required.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the ice
dispenser or in front of the louver.
7. This ice dispenser will not work at subfreezing
temperatures. To prevent damage to the
water supply line, drain the ice dispenser
when air temperature is below zero.
2. Electrical Connection
WARNING
THIS APPLIANCE MUST BE EARTHED
This ice dispenser requires an earth that
meets the national and local electrical code
requirements. To prevent possible severe
electrical shock to individuals or extensive
damage to equipment, install a proper earth
wire to the ice dispenser. Remove the plug
from the mains socket before any maintenance,
repairs, or cleaning is undertaken.
• This ice dispenser must have a separate power
supply or receptacle of proper capacity. See the
nameplate. It is recommended that this ice dispenser
be the only electrical device on its power supply
circuit.
• The main control box fuses are rated at 10A, 1A,
and 0.5A and should only be replaced by a qualified
service engineer.
• Usually an electrical permit and services of a licensed
electrician are required.
• If a power cord and/or a plug should need to be fitted/
replaced, it should only be done by a qualified service
engineer.
• Factory fitted power cords are coloured in accordance
with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
For the U.K. and the Republic of Ireland Only
• The non-rewirable plug must never be used without a
fuse cover being fitted.
• The correct replacement for the detachable fuse
cover is identifiable from the manufacturer’s reference
number stamped on the plug.
• Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
• Fuses should be rated at 10A and approved to
BS 1362.