49
Press the Set Button again to complete the setting and start icemaking operation in the ICE
mode.
2) Displaying Model Setting No.
Keep pressing the Option Button in the ICE or STOP mode.
The Display Window will show the compressor operating hours ([b] - 3).
Press and release the Ice Button.
The Display Window will show the freeze cycle time ([b] - 9).
When “– –“ appears, press and release the Ice Button.
The Display Window will show the active Model Setting No.
Release the Option Button to return to the original mode.
3) Displaying Compressor Operating Hours
Keep pressing the Option Button in the ICE or STOP mode.
The Display Window will show the compressor operating hours.
“00” indicates the operating hours less than 1,000 hours.
“01” indicates not less than 1,000 hours but less than 2,000 hours.
¦
“25” indicates not less than 25,000 hours but less than 26,000 hours.
4) Resetting Compressor Operating Hours
Do not use this command unless necessary.
With the Operation Switch in the OFF position, keep pressing the Ice + Stop + Option
Buttons together, and turn ON the Operation Switch.
Release the Buttons when the Display Window shows the ICE mode.
The Compressor will start 15 seconds after completion of water supply.
The compressor operating hours has been reset.
5) Displaying Error Record
Keep pressing the Option Button in the ICE or STOP mode.
The Display Window will show the compressor operating hours ([b] - 3).
Press and release the Stop Button to display the error record.
A maximum of eight most recent errors will be displayed in reverse order of occurrence,
including those not informed to the user.
“– –“ shows the end of the error record.
Release the Option Button to return to the original mode.
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...