9) Displaying Freeze Cycle Time
The five most recent freeze cycles are memorized and will be deleted by turning OFF
the Operation Switch.
Keep pressing the Option Button in the ICE or STOP mode.
The Display Window will show the compressor operating hours ([b] - 3).
Press and release the Ice Button to display the freeze cycle time (max. five cycles).
Release the Option Button to return to the original mode.
The freeze cycle time is displayed with two digits each for minutes [o - E] + [0 - 9] and
seconds [0 - 5] + [0 - 9].
Minutes
[o] + [0 - 9]
=
0 - 9 min
[A] + [0 - 9]
= 10 - 19 min
[b] + [0 - 9]
= 20 - 29 min
[C] + [0 - 9]
= 30 - 39 min
[d] + [0 - 9]
= 40 - 49 min
[E] + [0 - 9]
= 50 - 59 min
Seconds
[0 - 5] + [0 - 9]
(Example)
[o] + [9] [4] + [8] = 9 minutes 48 seconds
[b] + [7] [3] + [6] = 27 minutes 36 seconds
An approximate ice production capacity can be calculated from the freeze cycle time:
Flake
Ice production capacity (kg/d) = 66,000 / cycle time (sec)
Nugget
Ice production capacity (kg/d) = 65,000 / cycle time (sec)
This is just an approximate ice production capacity. The capacity depends on ambient
temperature, water temperature, voltage, and frequency. To determine an accurate
capacity, use a container to receive ice produced for 10 minutes, measure its weight, and
convert it into daily production. Take three measurements, and calculate their average.
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Page 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...