55
9. ERROR CODES
Interlock Errors
Code
Error
Condition
Operation
Reset
Check/Repair
E0
Icemaking Water
Leak
Following initial water
supply, Float Switch trips
at lower float level after
Gear Motor starts and
before Compressor starts.
Whole unit
stops.
Press Reset
Button.
Water leak, Flush
Water Valve not
closing, Float Switch
E1
Low Ice
Production
Icemaking cycle takes too
long.
Whole unit
stops.
Press Reset
Button.
Gas leak, Control
Water Valve not
closing, Vapor lock,
Freeze up, Float
Switch
E2
Float Switch
Error
With Flush Water Valve
OFF, Float Switch trips at
both upper and lower float
levels for 2 seconds.
Whole unit
stops.
Press Reset
Button.
Float Switch
Gear Motor is ON with
Rotation Sensor or Current
Sensor circuit open.
E3
Gear Motor Error
or Gear Motor
Sensor Circuit
Open
Gear Motor Relay is ON
with Gear Motor protective
circuit detector OFF.
Whole unit
stops.
Press Reset
Button.
Rotation Sensor,
Current Sensor Gear
Motor protective
circuit (TPO,
Overload, etc.)
E4
Abnormal High
Side Pressure
c2 error occurs 5 times in 1
hour of Compressor
operation.
E4 blinks.
N/A
Fan Motor, Cooling
water circuit,
Refrigeration circuit,
Condenser clogged,
Water supply,
Installation conditions
E5
Gear Motor
Drive Element
Error
Gear Motor is OFF on
Controller Board while
Rotation Sensor signals
Gear Motor rotation or
current flows.
Whole unit
stops.
Press Reset
Button.
Miswiring, Gear
Motor Magnet Switch
or Relay Replace
Controller Board.
E8
Discharge Pipe
Temperature
Error
Discharge Pipe
Thermostat is OFF.
Whole unit
stops.
Press Reset
Button.
Gas leak,
Compressor Cooling
Fan failure
EA
Water
Temperature
Thermistor
Circuit Open
Water Temperature
Thermistor circuit is open.
EA blinks.
N/A
Water Temperature
Thermistor
Eb
Condenser
Center
Thermistor
Circuit Open
Condenser Center
Thermistor circuit is open.
Eb blinks.
N/A
Condenser Center
Thermistor
EC
Resistor Circuit
Open
Resistor circuit is open.
Whole unit
stops.
Press Reset
Button.
Resistor
Ed
Abnormal Gear
Motor Current
Current Sensor detects
locked or hunting Gear
Motor.
Whole unit
stops.
Press Reset
Button.
Gear Motor locked,
hunting or
overloaded
Rotation Sensor detects
reversing.
EE
Gear Motor
Rotation Error
Rotation rate reduces with
current higher than setting
and voltage exceeding low
voltage reset setting.
Whole unit
stops.
Press Reset
Button.
Gear Motor locked,
hunting, reversing or
overloaded
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Page 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...