56
Code
Error
Condition
Operation
Reset
Check/Repair
EF
Frequent
Voltage Error
c3 error occurs 3 times in
24 hours.
Whole unit
stops.
Press Reset
Button.
Supply voltage
EJ
Gear Motor
Failure
Precaution
Ed and EE occur 10 times
in total.
EJ blinks.
N/A
Replace Evaporator
and Gear Motor.
EL
Bin Control
Switch Error
Bin Control Protective
Switch trips.
Whole unit
stops.
Press Reset
Button.
Bin Control Switch
En
Low Voltage
Sensing
Transformer
Circuit Open
Low Voltage Sensing
Transformer circuit is open.
Whole unit
stops.
Press Reset
Button.
Low Voltage Sensing
Transformer
No model setting.
EP
Controller
Board Model
Setting Error
Unacceptable supply
frequency.
Whole unit
stops.
Press Reset
Button.
Model setting, Supply
frequency
EU
Controller Board
Error
Controller Board IC fails.
Whole unit
stops.
Press Reset
Button.
Replace Controller
Board.
None
Electric Leak
Short Circuit
Electric leak or
overcurrent.
Whole unit
stops.
Press Reset
Button.
Replace
Fuse.
Electric leak, Fuse
Non-Interlock Errors
Code
Error
Condition
Operation
Reset
Check/Repair
CM
Time
“
— —
”
Microcomputer
Read/Write
Error
Microcomputer fails to
read/write properly.
Memory circuit
not available.
Replace
Controller
Board.
Error records and
compressor
operating hours not
available on
display
c1
Low Water
Water supply
continues for more
than 90 seconds, or
Float Switch trips at
lower float level and
does not reset for
more than 60 seconds
after water supply.
Whole unit stops
until Reservoir
fills up. Only
Control Water
Valve operates
intermittently for
5 minutes.
Automatically
resets after
Reservoir fills
up.
Water supply
interruption,
Control Water
Valve not opening,
Flush Water Valve
not closing, Float
Switch, Water leak
c2
Abnormal High
Side Pressure
Pressure Switch stays
OFF for 5 seconds.
Whole unit
stops.
Automatically
resets after
Pressure
Switch turns
ON.
Condenser
clogged, Cooling
water circuit,
Refrigeration
circuit
c3
Abnormal Low
Voltage
Voltage stays below
setting for more than 1
second with
Compressor ON and
Control Water Valve
OFF.
c3 blinks.
Automatically
resets after
voltage stays
above reset
setting for 2
minutes.
Supply voltage
c4
Drain Error
Float Switch trips at
upper float level in 10
minutes after Flush
Water Valve turns ON.
Indication only.
N/A
Flush Water Valve
not opening,
Control Water
Valve not closing
c5
Gear Motor
Error
Rotation rate reduces.
Whole unit stops
except Control
Water Valve.
Automatically
resets after 2
minutes.
Gear Motor
overloaded
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Page 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...