61
IV. SERVICE DIAGNOSIS
Display error record by operating the Operation Board (See “III. 7. [b] 5) Displaying Error
Record”). Check for a possible cause and service the unit.
1. NO ICE PRODUCTION
PROBLEM POSSIBLE
CAUSE
REMEDY
1. OFF position.
1. Move to ON position.
2. Loose connections. 2.
Tighten.
3. Bad contacts.
3. Check for continuity and
replace.
4. Blown fuse.
4. Replace.
a) Power Supply
5. Voltage too low.
5. Get recommended voltage.
b) Fuse (Controller
Board)
1. Blown out. No
indication on
Operation Board.
1. Find out the cause of short
circuit (ex. Control Water
Valve, Flush Water Valve),
resolve it, and replace
Controller Board.
c) Transformer
Receptacle
1. Disconnected.
1. Connect.
1. OFF position.
1. Move to ON position.
d) Operation Switch
2. Bad contacts.
2. Check for continuity and
replace.
e) Transformer
1. Coil winding opened.
1. Replace.
f) Water Valve
1. Coil winding opened.
1. Replace.
1. Closed.
1. Open.
g) Water Supply
Tap
2. Water failure.
2. Wait till water is supplied.
1. Disconnected.
1. Connect.
h) Plug and
Receptacle
(Control Box)
2. Terminal out of Plug
or Receptacle.
2. Insert Terminal back in
position.
i) Chute Switch
1. Tripped.
1. See “III. 6. [i] CHUTE
SWITCH”.
j) Overload
Protector
1. Tripped.
2. Reset.
[1] The icemaker will
not start.
k) Model Setting No.
1. Incorrect.
2. Set correct No. See “III. 7. [b]
1) Setting Model No.”
1. Contacts fused.
1. Replace Controller Board.
a) Water Control
Relay (Controller
Board)
2. Coil winding opened.
2. Replace Controller Board.
1. Bad contacts.
1. Check for continuity and
replace.
b) Float Switch
2. Float does not move
freely.
2. Clean or replace.
c) Flush Water
Valve
1. Valve seat clogged
and water leaking.
1. Clean or replace.
d) Hoses
1. Disconnected.
1. Connect.
e) Mechanical Seal
1. Water leaks.
1. Replace.
[2] Water does not
stop, and the
icemaker will not
start.
f) Reservoir
1. Cracked.
1. Replace.
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Page 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...