background image

ENGLISH

4

Fig. 6

Fig. 7

Operation Panel

ICE

DRAIN

STOP

MODE

ICE      STOP    RESET

Once STOP Button is pushed, 

ICE  Button  cannot  start  ice 

production for 20 min.

Ice Button          Display

Stop Button

Reset Button

Operation Switch

IMPORTANT

1.  Check  the  conditions  and  quality  of  the  ice 

production.

2.  Do  not  use  ice  produced  in  the  trial  run.  It 

might be contaminated with foreign matter in 

the water circuit. Discard or flush down the 

drain.

3.  Clean the Storage Bin before use (see “III. 1. 

CLEANING” in Instruction Manual).

7. FINAL CHECKS

1) Is installation free of water leaks?

2) Is the icemaker free from vibration?

3) Are all the panels fixed and secure?

4) Has the user been instructed on correct machine 

use and handed the Instruction Manual?

6. START-UP PROCEDURE

1) Check that the power supply cord is disconnected.

2) Move  the  Operation  Switch  on  the  Operation 

Panel to the “ON” position.

3) Open the water supply tap.

4) Connect the power supply and energise.

5) The Display will illuminate in the “ICE” mode.

6) The following should occur in sequence:

a) Water Reservoir will fill.

b) Gear Motor will start.

c) Compressor will start.

Water Supply 

Inlet G3/4

Drain Outlet 

R3/4

Bin Drain Outlet 

3/4 FPT

Water Supply Line 

Shut-off Valve

Drain Valve

5cm air gap

Separate piping to approved 

drain. Leave a 5cm vertical 

air gap between the end of 

each pipe and the drain.

Drain

Floor

Summary of Contents for FM-300AFE-HC

Page 1: ...UNKER MAQUINA DE CUBITOS MODULAR FABBRICATORE MODULARE DI GHIACCIO INSTALLATION MANUAL NOTICE D INSTALLATION INSTALLATIONSANLEITUNG INSTALLATIE VOORSCHRIFT MANUAL DE INSTALACION MANUALE PER L INSTALLAZIONE FOR QUALIFIED INSTALLER ONLY RESERVE A L INSTALLATEUR FÜR DEN INSTALLATEUR VOOR DE BEVOEGDE INSTALLATEUR SOLAMENTE PARA INSTALADOR CUALIFICADO SOLTANTO PER INSTALLATORI QUALIFICATI ...

Page 2: ...for any further consultation that may be necessary WARNING The installation must be carried out by qualified personnel in accordance with current regulations according to the manufacturer s instructions 1 UNPACKING WARNING Children should not be allowed in reach of the packaging elements plastic bags and expanded polystyrene as they are potential sources of danger CAUTION 1 Do not lift or manoeuvr...

Page 3: ...r 5 This appliance is not suitable for installation in an area where a water jet could be used and where dripping is not allowed 6 Do not place anything on top of the icemaker or in front of the Louver 7 Avoid prolonged exposure of the appliance to direct sunlight 8 This appliance contains flammable refrigerant in its cooling unit maintenance and recharging must therefore only be carried out by au...

Page 4: ...coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red Should the socket outlets in the installation site not be suitable for the plug supplied with your product the plug must be removed cut off if it is moulded on plug and an appropriate...

Page 5: ...ker free from vibration 3 Are all the panels fixed and secure 4 Has the user been instructed on correct machine use and handed the Instruction Manual 6 START UP PROCEDURE 1 Check that the power supply cord is disconnected 2 Move the Operation Switch on the Operation Panel to the ON position 3 Open the water supply tap 4 Connect the power supply and energise 5 The Display will illuminate in the ICE...