35
[e] RESETTING ERROR LOG
With the operation switch in the “OFF” position, press and hold the stop and maintenance A
buttons. Move the operation switch to the “ON” position. Release the buttons when the
display shows the ice mode. Now the error log is reset. Do not reset more than necessary.
[f] RESETTING COMPRESSOR OPERATING HOURS
With the power switch turned off, press and hold the ice, stop and maintenance A buttons.
Move the operation switch to the “ON” position. Release the buttons when the display shows
the ice mode. Now the compressor operating hours are reset.
When the compressor starts in 15 seconds after the water supply cycle ends, the error log is
not set to be updated. After resetting the compressor operating hours, move the operation
switch to the “OFF” position, turn off the power switch, and turn it back on.
Summary of Contents for FM-300AKE-HC
Page 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a FM 300AKE HC Auxiliary code D 0 or earlier ...
Page 5: ...2 b FM 300AKE HC Auxiliary code D 1 or later ...
Page 6: ...3 c FM 300AKE HCN Auxiliary code D 0 or earlier ...
Page 7: ...4 d FM 300AKE HCN Auxiliary code D 1 or later ...
Page 8: ...5 e FM 480AKE HC Auxiliary code D 0 or earlier ...
Page 9: ...6 f FM 480AKE HC Auxiliary code D 1 or later ...
Page 10: ...7 g FM 480AKE HCN Auxiliary code D 0 or earlier ...
Page 11: ...8 h FM 480AKE HCN Auxiliary code D 1 or later ...
Page 21: ...18 2 WIRING DIAGRAM a WIRING DIAGRAM FM 300AKE HC N Auxiliary code D 0 or earlier ...
Page 22: ...19 FM 300AKE HC N Auxiliary code D 1 or later ...
Page 23: ...20 FM 480AKE HC N Auxiliary code D 0 or earlier ...
Page 24: ...21 FM 480AKE HC N Auxiliary code D 1 or later ...
Page 33: ...30 b TIMING CHART ...