44
PROBLEM POSSIBLE
CAUSE
REMEDY
1. Dirty condenser fins. 1.
Clean.
2. Ambient temperature
too warm.
2. Check for recommended
temperature.
3. Fan not rotating.
3. Replace.
4. Condenser water
pressure too low or off.
4. Check and get recommended
pressure.
5. Water regulating valve
clogged.
5. Clean.
6. Refrigerant
overcharged.
6. Recharge.
7. Refrigerant line or
components plugged.
7. Clean and replace drier.
8. Bad contacts.
8. Check for continuity and
replace.
d) Pressure switch,
condenser
thermistor
9. Loose connections. 9.
Tighten.
1. Ambient temperature
too warm.
1. Check for recommended
temperature.
2. Compressor cooling
fan motor defective.
2. Replace.
3. Bad contacts.
3. Check for continuity and
replace.
e) Thermostat
(water-cooled
model)
4. Loose connections. 4.
Tighten.
1. Coil winding opened. 1.
Replace.
[3] (Continued)
f) Gear motor
protect relay
2. Bad contacts.
2. Check for continuity and
replace.
1. Bad contacts.
1. Check for continuity and
replace controller board.
a) X4 relay
(controller board)
2. Coil winding opened.
2. Replace controller board.
1. Bad contacts.
1. Check for continuity and
replace X6 relay.
b) X6 relay
2. Coil winding opened.
2. Replace X6 relay.
1. Loose connections. 1.
Tighten.
2. Motor winding opened
or earthed.
2. Replace.
b) Compressor
3. Motor protector
tripped.
3. Find out the cause of overheat
or overcurrent.
c) Power supply
1. Circuit ampacity too
low.
1. Install a larger-sized
conductor.
d) Controller board
1. Defective.
1. Replace
[4] Gear motor
starts, but
compressor will
not start or
operates
intermittently.
e) Start capacitor or
run capacitor
1. Defective.
1. Replace
1. Gas leaks.
1. Check for leaks with a leak
detector. Reweld leak, replace
drier and charge with
refrigerant. The amount of
refrigerant is marked on
nameplate or label.
[5] Gear motor and
compressor
start, but no ice
is produced.
a) Refrigerant line
2. Refrigerant line
clogged.
2. Replace the clogged
component.
Summary of Contents for FM-300AKE-HC
Page 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a FM 300AKE HC Auxiliary code D 0 or earlier ...
Page 5: ...2 b FM 300AKE HC Auxiliary code D 1 or later ...
Page 6: ...3 c FM 300AKE HCN Auxiliary code D 0 or earlier ...
Page 7: ...4 d FM 300AKE HCN Auxiliary code D 1 or later ...
Page 8: ...5 e FM 480AKE HC Auxiliary code D 0 or earlier ...
Page 9: ...6 f FM 480AKE HC Auxiliary code D 1 or later ...
Page 10: ...7 g FM 480AKE HCN Auxiliary code D 0 or earlier ...
Page 11: ...8 h FM 480AKE HCN Auxiliary code D 1 or later ...
Page 21: ...18 2 WIRING DIAGRAM a WIRING DIAGRAM FM 300AKE HC N Auxiliary code D 0 or earlier ...
Page 22: ...19 FM 300AKE HC N Auxiliary code D 1 or later ...
Page 23: ...20 FM 480AKE HC N Auxiliary code D 0 or earlier ...
Page 24: ...21 FM 480AKE HC N Auxiliary code D 1 or later ...
Page 33: ...30 b TIMING CHART ...