Dip Switch Setting (Main Board)
No.
1
2
3
4
5
6
ON
Modular
Type
Icemaking
Timer 1
Chute Switch
Normally open
contact (Current)
Rotation
Sensor OFF
Low Voltage Sensor ON
Automatic Drain Every 6h
Micro-
computer
Check
OFF
Self-
contained
Type
Icemaking
Timer 2
Chute Switch
Normally closed
contact (Revision)
Rotation
Sensor ON
Low Voltage Sensor OFF
Automatic Drain Every 12h
(External timer setting available)
Normal
Operation
Icemaking Timer Setting
Dip Switch 2
ON
OFF
ON
1st cycle:
30 minutes
2nd cycle and after:
15 minutes
1st cycle:
20 minutes
2nd cycle and after:
10 minutes
Dip Switch 1
OFF
1st cycle:
59 minutes
2nd cycle and after:
30 minutes
1st cycle:
59 minutes
2nd cycle and after:
20 minutes
±5% accuracy
Main Controller Board Drawing Nos. and Dip Switch Setting
Dip Switch
Drawing
No.
1
2
3
4
5
6
Factory
Inspection
Marking
Applicable Models
459866-04
459866-14
ON
ON
OFF
OFF
ON
OFF
H9
Modular type with
Rotation Sensor
(FM-481 etc.)
459866-06
459866-16
ON
ON
OFF
ON
ON
OFF
Hb
Modular type
(FM-1000ASFE3 etc.)
459866-07
459866-17
OFF
ON
OFF
ON
ON
OFF
Fb
Self-contained type
(CM-100 etc.)
459866-08
459866-18
ON
ON
ON
ON
ON
OFF
N/A
Service parts
(FM-1000ASFE3 with
K-1, K-2, A-0 only)
459866-09
459866-19
ON
ON
ON
OFF
OFF
OFF
N/A
Service parts
Controller Board - Main (HO4042-100: 458033-04) [Early Version]
Dip Switch Setting (UK/CONT.)
Dip Switch
Model
1
2
3
4
5
6
FM-1000ASFE3
(K-1, K-2, A-0)
ON
ON
ON
OFF
ON
OFF
Note: This Controller Board - Main (HO4042-100: 458033-04) will not be supplied as a service part.
For replacement, order the “Improved Version” according to the Parts List.
E2AH5820209
21