PROBLEM
POSSIBLE CAUSE
REMEDY
[1] (Continued)
g) CPR (Condenser
Unit)
1. Internal leaks.
1. Replace.
a) Water Supply
1. Water pressure too
high.
1. Install a Pressure
Reducing Valve.
b) Water Valve
1. Diaphragm does not
close.
1. Clean or replace.
[2] Overflow from
Reservoir
(Water does
not stop.)
c) Float Switch
1. Bad contacts.
1. Check for continuity and
replace.
a) Power Supply
Voltage
1. Too high or too low.
1. Connect the unit to a power
supply of proper voltage.
[3] Gear Motor
Protector
operates
frequently.
b) Evaporator Assy
1. Bearings or Auger
worn out.
1. Replace Bearing or Auger.
50