background image

ENGLISH

1

WARNING

Do not wet this product or use it in 

potentially wet conditions. This may 

cause electric leakage, resulting in 

electric shock or fire.

IMPORTANT

1. This is a commercial refrigerator/freezer 

and should be destined only yo be used 

for the purpose for witch it has been 

expressly designed.Any other use should 

be considered improper and therefore 

dangerous. The manufacturer will not be held 

liable or responsible for any damage caused 

by improper, incorrect and unreasonable 

use.

2. This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, 

or lack of experience and knowledge, 

unless they have been given supervision or 

instruction concerning use of the appliance 

by a person responsible for their safety. 

Young children should be supervised 

to ensure that they do not play with the 

appliance.

3. Keep ventilation openings, in the appliance 

enclosure or in the built-in structure, clear of 

obstruction. 

4. Do not use mechanical devices or other 

means to accelerate the defrosting process, 

other than those recommended by the 

manufacturer. 

5. Do not damage the refrigerant circuit. 

6. Do not use electrical appliances inside the 

food storage compartments of the appliance, 

unless they are of the type recommended by 

the manufacturer. 

7.Before proceeding with cleaning and 

maintenance operations, make sure the 

power line of the unit is disconnected

8. Do not connect or disconnect the electric 

plug when your hands are wet. 

9. Do not store explosive substances such as 

aerosol cans with a flammable propellant in 

this appliance.

10.  Do  not  store  or  use  gasoline  or  any  other            

flammable vapors and liquids 

11. If the supply cord is damaged, it must be 

replaced by the manufacturer, its service 

agent  or  similarly  qualified  persons  in  order 

to avoid a hazard

13. Any repairs and work on the appliance 

should only be carried out by the customer 

service department/ qualified technician

14. This instruction manual can be downloaded 

in following website: http://www.hgec.net/

download/

15. Maximum loading of each shelf is 60 kg

16. Noise level is far below from legal limit of 70 

dB

I. INSTALLATION INSTRUCTIONS

1. CONSTRUCTION

2. ACCESSORIES

Width 

900mm  1200/1500mm  1800mm

a) Shelf: 

2 [2] 

4 [4] 

6 [6]

b) Shelf clip: 

8 [8] 

16 [16] 

24 [24]

c) Shelf holder:  5 [0] 

10 [0] 

15 [0]

d) Spanner: 

1 [1] 

1 [1] 

1 [1]

    (Only for caster)

e) spacer: 

5 [5] 

4 [4] 

4 [4]

    (Only for caster)

Note: 1. Numbers in parentheses are for models 

without shelf holders.

 

2. Customized products may have different 

numbers and specifications of accessories.

Keep Dry

Machine Compartment

Fig. 1

Front Panel

Front Panel 

Air Outlet

Door (L)

Door (R)

Top Panel

Front Panel 

Air Inlet

Caster

Shelf

Window Panel

Fig. 2

Power Cord

Summary of Contents for FT-126MA-A

Page 1: ...TION MANUAL This booklet is an integral and essential part of the product and should be kept and preserved by the user Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer user with essential information for the proper installation and the continued safe use and maintenance of the product Please preserve this booklet for any further consu...

Page 2: ...ICAL CONNECTIONS 3 II OPERATING INSTRUCTIONS 3 1 START UP 4 2 CABINET TEMPERATURE SETTING 4 3 DEFROST 5 4 INDICATOR LIGHTS 5 5 SHUT DOWN 5 III MAINTENANCE 5 1 INTERIOR EXTERIOR SHELF 6 2 AIR FILTER 6 3 BEFORE CALLING A SERVICE AGENT 6 a TROUBLES WITH ERROR CODE INDICATION 7 b TROUBLES WITHOUT ERROR CODE INDICATION 7 4 DISPOSAL 7 5 WARRANTY 7 ...

Page 3: ...nless they are of the type recommended by the manufacturer 7 Before proceeding with cleaning and maintenance operations make sure the power line of the unit is disconnected 8 Do not connect or disconnect the electric plug when your hands are wet 9 Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance 10 Do not store or use gasoline or any other flamma...

Page 4: ...lly a side by side or back to back installation possibly with other manufacturer s unit may cause condensation between the two units resulting in dripping onto the floor Do not expose the unit to direct sunlight or higher temperatures Allow at least 50 cm clearance between the front panel air inlet outlet and the wall or other equipment for proper air circulation The front of the unit should have ...

Page 5: ...lders to prevent damage to the cabinet bottom resulting in corrosion 6 ELECTRICAL CONNECTIONS IMPORTANT This refrigerator freezer is provided with no power switch or earth leakage circuit breaker but with overcurrent protection fuse only Install a switch rated at least 10A on the main power supply This refrigerator freezer must be plugged into the separated power receptacle which is readily access...

Page 6: ...e refrigerator and 20 C for the freezer If necessary readjust the temperature as follows some space between them to ensure good air flow 12 Do not put in warm or hot foods Let them cool first or they will raise the cabinet temperature and could deteriorate other foods in the cabinet or overload the refrigerator freezer 13 Make sure all items are snug on each shelf 7 Do not use combustible spray or...

Page 7: ...om the actual temperature depending on arrangement of stored foods frequency of door opening or measuring points III MAINTENANCE IMPORTANT 1 Before carrying out any cleaning or maintenance operations unplug the unit 2 D o n o t t o u c h o r w e t t h e m a c h i n e compartment parts This could result in failure or breakdown 3 To prevent possible damage do not clean the plastic parts with water a...

Page 8: ... Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting clogged If the filters get clogged the refrigerator freezer s performance will be reduced Check the filter at least twice a month When clogged or when the temperature controller shows cH use warm water and a neutral cleaner to wash the filter Do not operate the unit with the air filter removed or the con...

Page 9: ... Service office a TROUBLES WITH ERROR CODE INDICATION Code Possible Cause Remedy E1 Cabinet sensor error Immediately contact an authorized Hoshizaki service company E2 Evaporator sensor error E3 Condenser sensor error The code dEF is not an error code but indicates the unit is in defrost cycle b TROUBLES WITHOUT ERROR CODE INDICATION 1 Unit fails to operate 1 Unplugged 2 Power failure 3 Main power...

Page 10: ...apore 609966 Tel 65 6225 2612 Fax 65 6225 3219 Hoshizaki Taiwan Inc 5F No 337 Sec 1 Dunhua S Rd Da an Dist Taipei City 106 Taiwan R O C Tel 886 2 2706 8818 Fax 886 2 2708 7999 Hoshizaki Lancer Pty Ltd 5 Toogood Avenue Beverley SA 5009 Australia Tel 61 8 8268 1388 Fax 61 8 8268 1978 info hoshizaki com au http www hoshizaki com au To register your product for warranty with Hoshizaki visit http www h...