28
COM.
N.O.
N.C.
DEFROST
FREEZE
Holder
Screw
Thermistor
Evaporator
[b] BEFORE CHECKING CONTROLLER BOARD
Check the power source voltage and the components as shown in the table below.
Component
1. Actuator Toggle
Switch
2. Thermistor
(on Evaporator)
3. Bin Control Switch
Procedure
Manually set the switch in the FREEZE
and DEFROST positions, and check the
continuity.
CAUTION
Thermistor Sensor part is fragile,
glass sealed. Handle with care.
* Disconnect the Connector K4 on the
board.
* Remove the screw and the Thermistor
Holder on the Evaporator.
* Immerse the Sensor part in a glass
containing ice and water for 5 minutes.
* Check the resistance between K4
Connector Pins.
* Replace the Thermistor in its correct
position.
* Connect K4.
Manually set the Micro Switch in the
TRIP and RESET positions, and check
the period.
Normal
DEFROST
COM-NO
Open
COM-NC
Closed
FREEZE
COM-NO
Closed
COM-NC
Open
5 -7 kilohms
Approx.
TRIP(Closed) 10 sec.
RESET(Open) 80 sec.
Summary of Contents for IM-100
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Page 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Page 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Page 8: ...4 d IM 45LE Air cooled ...
Page 9: ...5 e IM 45CLE 25 Air cooled ...
Page 10: ...6 f IM 65LE Air cooled ...
Page 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Page 12: ...8 h IM 100CLE Air cooled ...
Page 13: ...9 i IM 160ME Air cooled ...
Page 14: ...10 j IM 240ME Air cooled ...
Page 15: ...11 k IM 240M2E Air cooled ...
Page 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Page 17: ...13 m IM 45WLE Water cooled ...
Page 18: ...14 n IM 65WLE Water cooled ...
Page 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Page 20: ...16 p IM 240WME Water cooled ...
Page 21: ...17 q IM 240WM2E Water cooled ...
Page 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Page 71: ...67 b IM 25L IM 25CL IM 25WL ...
Page 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Page 73: ...69 d IM 65LE IM 65WLE ...
Page 74: ...70 e IM 65L IM 65WL ...
Page 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 80: ...76 k IM 160ME ...
Page 81: ...77 l IM 240ME IM 240WME ...
Page 82: ...78 m IM 240M2E IM 240WM2E ...
Page 120: ...116 Fig 30 ...