38
3. The location should provide a firm and level foundation for the equipment at
normal counter top height.
4. Allow 15 cm clearance at rear, sides and top for proper air circulation and
ease of maintenance and/or service should they be required.
5. This appliance is not suitable for installation in an area where a water jet
could be used and where dripping is not allowed.
6. Do not place anything on top of the icemaker or in front of the Louver.
7. This icemaker will not work at subfreezing temperatures. To prevent damage
to the water supply line, drain the icemaker when air temperature is below
zero (see “IV. 2. PREPARING THE ICEMAKER FOR LONG STORAGE”).
3. INSTALLATION
* Incorrect installation can cause harm to people, animals or things, for which the manufacturer
cannot be held responsible.
* Place the icemaker in the selected permanent site.
4. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED.
This icemaker requires an earth that meets the national and local electrical code
requirements. To prevent possible severe electrical shock injury to individuals
or extensive damage to equipment, install a proper earth wire to this icemaker.
Remove the plug from the mains socket before any maintenance, repairs or
cleaning is undertaken.
* This icemaker must have a separate power supply or receptacle of 220 - 240V.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service
engineer.
* Usually an electrical permit and services of a licensed electrician are required.
* If the supply cord and the plug should need to be replaced, it should only be done by a
qualified service engineer.
Summary of Contents for IM-100
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Page 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Page 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Page 8: ...4 d IM 45LE Air cooled ...
Page 9: ...5 e IM 45CLE 25 Air cooled ...
Page 10: ...6 f IM 65LE Air cooled ...
Page 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Page 12: ...8 h IM 100CLE Air cooled ...
Page 13: ...9 i IM 160ME Air cooled ...
Page 14: ...10 j IM 240ME Air cooled ...
Page 15: ...11 k IM 240M2E Air cooled ...
Page 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Page 17: ...13 m IM 45WLE Water cooled ...
Page 18: ...14 n IM 65WLE Water cooled ...
Page 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Page 20: ...16 p IM 240WME Water cooled ...
Page 21: ...17 q IM 240WM2E Water cooled ...
Page 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Page 71: ...67 b IM 25L IM 25CL IM 25WL ...
Page 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Page 73: ...69 d IM 65LE IM 65WLE ...
Page 74: ...70 e IM 65L IM 65WL ...
Page 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 80: ...76 k IM 160ME ...
Page 81: ...77 l IM 240ME IM 240WME ...
Page 82: ...78 m IM 240M2E IM 240WM2E ...
Page 120: ...116 Fig 30 ...