(Ice Production = Capacity when shipped from factory)
(*Values for icemaking water only. Use a cooling tower for cooling water.)
Ambient Temp. (°C)
10
21
32
38
Model
Water Temp. (°C)
10
15
21
32
Ice Production (kg/d)
217
210
190
170
Freeze Cycle Time (min)
10
10
11.1
13.2
Defrost Cycle Time (min)
3
3
2.5
2
Water Consumption (lit/h)*
43
25.5
15
12.5
Electric Consumption (W)
1120
1200
1330
1450
IM-240M2E-21
(50Hz)
Head Pressure [median] (bar)
16
17.5
23
26
Ice Production (kg/d)
220
210
180
185
Freeze Cycle Time (min)
10
11.4
14.3
14.3
Defrost Cycle Time (min)
3.5
3
2.5
2
Water Consumption (lit/h)
50
36
17
13.3
Electric Consumption (W)
1450
1500
1600
1640
IM-240M2E-21
(60Hz)
Head Pressure [peak] (bar)
16.3
17.8
23.3
26.3
Ice Production (kg/d)
235
215
200
185
Freeze Cycle Time (min)
15
16.5
18.5
21
Defrost Cycle Time (min)
3.5
3.5
3
2.5
Water Consumption (lit/h)* 30 23.8 18.4 13.8
Electric Consumption (W)
1250
1250
1300
1300
IM-240WME
(50Hz)
Head Pressure [median] (bar)
19
19
19
19
Ice Production (kg/d)
210
202
185
175
Freeze Cycle Time (min)
12
13.2
15.2
16.7
Defrost Cycle Time (min)
3.5
3
2.5
2
Water Consumption (lit/h)* 30.4 24.6 17.1 14.1
Electric Consumption (W)
1250
1250
1300
1300
IM-240WME-23
(50Hz)
Head Pressure [median] (bar)
19
19
19
19
Ice Production (kg/d)
190
185
175
160
Freeze Cycle Time (min)
13.7 14.7 16.2 18.4
Defrost Cycle Time (min)
3.5
3
2.5
2
Water Consumption (lit/h)* 26.9 22.8 18.3 13.8
Electric Consumption (W)
1430
1450
1500
1550
IM-240WME-23
(60Hz)
Head Pressure [median] (bar)
19.4
19.4
19.5
20
Ice Production (kg/d)
215
207
195
180
Freeze Cycle Time (min)
10
10
10.8
12.4
Defrost Cycle Time (min)
3.5
3
2.5
2
Water Consumption (lit/h)* 31.7 27.1 23 18.3
Electric Consumption (W)
1250
1250
1300
1300
IM-240WME-21
(50Hz)
Head Pressure [median] (bar)
19
19
19
19
Ice Production (kg/d)
205
195
190
185
Freeze Cycle Time (min)
11.3 12.5 13.4 13.8
Defrost Cycle Time (min)
3.5
3
2.5
2.5
Water Consumption (lit/h)* 34.2 28.8 24.2 20.9
Electric Consumption (W)
1430
1450
1500
1550
IM-240WME-21
(60Hz)
Head Pressure [median] (bar)
19.4
19.4
19.5
20
Ice Production (kg/d)
235
215
200
185
Freeze Cycle Time (min)
15
16.5
18.5
21
Defrost Cycle Time (min)
3.5
3.5
3
2.5
Water Consumption (lit/h)* 30 23.8 18.4 13.8
Electric Consumption (W)
1250
1250
1300
1300
IM-240WM2E
(50Hz)
Head Pressure [median] (bar)
19
19.2
19.3
20
87
Summary of Contents for IM-100
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Page 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Page 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Page 8: ...4 d IM 45LE Air cooled ...
Page 9: ...5 e IM 45CLE 25 Air cooled ...
Page 10: ...6 f IM 65LE Air cooled ...
Page 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Page 12: ...8 h IM 100CLE Air cooled ...
Page 13: ...9 i IM 160ME Air cooled ...
Page 14: ...10 j IM 240ME Air cooled ...
Page 15: ...11 k IM 240M2E Air cooled ...
Page 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Page 17: ...13 m IM 45WLE Water cooled ...
Page 18: ...14 n IM 65WLE Water cooled ...
Page 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Page 20: ...16 p IM 240WME Water cooled ...
Page 21: ...17 q IM 240WM2E Water cooled ...
Page 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Page 71: ...67 b IM 25L IM 25CL IM 25WL ...
Page 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Page 73: ...69 d IM 65LE IM 65WLE ...
Page 74: ...70 e IM 65L IM 65WL ...
Page 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 80: ...76 k IM 160ME ...
Page 81: ...77 l IM 240ME IM 240WME ...
Page 82: ...78 m IM 240M2E IM 240WM2E ...
Page 120: ...116 Fig 30 ...