28
Control Board (CB) Setting Menu
Category
No. Item
Range
IM-200BAC
Default
Other
21 Stackable Bin Control
Allows for stacked units to be controlled through one bin
control.
DO NOT ADJUST
Yes=1; No=0
1
22 Refrigeration Circuit Cycling when Bin Full
DO NOT ADJUST
On=1; Off=0
0
Model
30 Type
0: WC, PS, No CondTherm, Ignore CB Setting 34
1: AC, No PS, No CondTherm, Use CB Setting 34
2: AC, No PS, CondTherm, Use CB Setting 34
3: AC, PS, No CondTherm, Use CB Setting 34
DO NOT ADJUST
0 to 3
3
Harvest
Cycle High
Temperature
Control
34 Harvest Cycle High Temperature Control
Active if type setting (CB Setting 30) is set to 1, 2, or 3.
If control board thermistor temperature at the beginning of
harvest cycle is equal to or greater than the harvest cycle
high temperature control setting, fan motor operates
continuously in harvest cycle.
40 to 70°C
(1°C increments)
48
Water
Regulating
Valve
36 Water Regulating Valve Error Detection Temperature
DO NOT ADJUST
0 to 50°C
0=ignore, air-cooled
model
(1°C increments)
0
Compressor 37 Compressor Output Selection
DO NOT ADJUST
0: X8 (DC Relay)
On
1: X1 (AC Relay) On
1
Anti-Slush
Control
50 Pump De-Energized Time
When temperature at evaporator (cube control) thermistor
drops to 37°F (3°C) in the freeze cycle, pump
de-energizes for the length of time set.
0 to 90 sec.
0=ignore, no anti-
slush
(1 sec. increments)
0
51 Anti-Slush Control Water Supply Time
Time inlet water valve is energized while pump is
de-energized if pump de-energized time (CB Setting 50) is
greater than 0.
0 to 5 sec.
(1 sec. increments)
0
Hard Water
Control
60 Integrated Value
If hard water control water supply time (CB Setting 61) is
greater than 0: After evaporator (cube control) thermistor
indicates temperature of 32°F (0°C) in freeze cycle, inlet
water valve energized starting when percentage of freeze
cycle termination temperature and freeze cycle time
integrated value has been achieved.
DO NOT ADJUST
10 to 100%
(00=100)
(1% increments)
10
61 Hard Water Control Water Supply Time
Time inlet water valve is energized after integrated value
(CB Setting 60) conditions are met.
Before using this setting, follow the instructions to improve
ice clarity; see "III.G.2. Ice Clarity."
0 to 90 sec.
(1 sec. increments)
0