C. Control Board Settings
NOTICE
Failure to maintain factory settings may adversely affect performance and warranty
coverage. For more information, contact your Hoshizaki Service Center.
1) With "on" in display, press and hold the "RESET" button for 3 seconds. Display changes
to "1".
2) Use the "SERVICE 1" and "SERVICE 2" buttons to choose a control board setting.
3) Press the "RESET" button to view the setting’s value. Current value flashes in display.
4) Use the "SERVICE 1" and "SERVICE 2" buttons to change value.
5) Press the "RESET" button to select value. Display returns to control board setting
number.
6) Once display returns to "on" (20 seconds), the new setting is saved.
Control Board (CB) Setting Menu
Category
No. Item
Range
IM-200BAC
Default
Basic
1 Harvest Cycle Termination Temperature
Temperature to complete harvest cycle.
2 to 20°C
(1°C increments)
5
2 Freeze Cycle Termination Temperature
Integrated with freeze cycle termination time (CB Setting
3) to control length of freeze cycle after evaporator (cube
control) thermistor temperature drops to 32°F (0°C). To use
this setting for dimple size adjustment, see "III.G.1. Dimple
Diameter."
-5 to -40°C
(0.5°C increments.
The "." in the lower,
right corner of the
display indicates
.5°C.)
-22.5
3 Freeze Cycle Termination Time
Integrated with freeze cycle termination temperature (CB
Setting 2) to control length of freeze cycle after evaporator
(cube control) thermistor temperature drops to 32°F (0°C).
5 to 90 min.
(1 min. increments)
17
4 Ambient Temperature Correction Value for Freeze Cycle
Termination
DO NOT ADJUST
10 to 50°C
(1°C increments)
39
5 Ambient Temperature Correction Rate for Freeze Cycle
Termination
DO NOT ADJUST
10 to 100%
(00 = 100) (1%
increments)
90
6 Freeze Cycle Backup Timer
Maximum allowed freeze time to prevent possible freeze-up
issues.
45 to 90 min.
(5 min. increments)
50
Water
Supply
10 Harvest Cycle Water Supply Time: Water Temperature
48°F (9°C) or Lower
When set to "99", inlet water valve energized until harvest
cycle termination temperature (CB Setting 1) is reached.
1 to 99 sec,
99 = continuous
(1 sec. increments)
98
11 Harvest Cycle Water Supply Time: Water Temperature
Higher Than 48°F (9°C)
When set to "99", inlet water valve energized until harvest
cycle termination temperature (CB Setting 1) is reached.
1 to 99 sec,
99 = continuous
(1 sec. increments)
24