3. ABNORMAL ICE
PROBLEM
CHECK
POSSIBLE CAUSE
REMEDY
a) Water Supply
Line
1. Low pressure.
1. Check for recommended
pressure.
b) Ambient or
Water
Temperature
1. Too high.
1. Check for recommended
temperatures.
c) Air Filter,
Condenser
1. Clogged.
1. Clean.
d) Water Valve
1. Clogged.
1. Clean.
1. Leaks.
1. Repair or replace.
2. Bearings worn out.
2. Replace.
e) Pump Motor
3. Mechanical Seal worn
out.
3. Replace.
f) Refrigerant
Charge
1. Undercharged.
1. Check for leaks and
recharge correctly.
g) Thermistor,
Controller Board
1. See “II. 2. CONTROLLER BOARD”.
[1] Large-hole
cubes.
h) Expansion
Valve
1. Poorly adjusted.
1. Readjust.
1. Low pressure.
1. Check for recommended
pressure.
a) Water Supply
Line
2. Clogged.
2. Check Strainer and
clean.
1. High hardness or
contains impurities.
1. Install a water filter or
scale treatment.
b) Water Quality
2. Lime is deposited inside
Cooling Water Tubing.
2. Clean.
c) Water Valve
1. Clogged.
1. Clean.
d) Water System
1. Scaled up.
1. Clean or remove scale.
e) Water Plate
1. Jet hole clogged.
1. Clean.
1. Leaks.
1. Replace.
2. Bearings worn out.
2. Replace.
f) Pump Motor
3. Mechanical Seal worn
out.
3. Replace.
[2] Cloudy cubes.
g) Thermistor,
Controller Board
1. See “II. 2. CONTROLLER BOARD”.
a) Extension
Spring
1. Over-extended.
1. Replace.
b) Clearance
between
Evaporator and
Water Plate
1. Too much.
1. Readjust.
c) Evaporator
1. Dirty or scaled up.
1. Clean or remove scale.
[3] Slab does not
break into
separate
cubes.
d) Thermistor,
Controller Board
1. See “II. 2. CONTROLLER BOARD”.
68
E1CG4880210
Summary of Contents for IM-240AME
Page 6: ...2 2 E1CG4880210 E1CG4880210 b IM 240DWME Water cooled b IM 240DWME Water cooled ...
Page 7: ...3 3 E1CG4880210 E1CG4880210 c IM 240DSME Remote Air cooled c IM 240DSME Remote Air cooled ...
Page 8: ...4 4 E1CG4880210 E1CG4880210 d IM 240XME Air cooled d IM 240XME Air cooled ...
Page 9: ...5 5 E1CG4880210 E1CG4880210 e IM 240XWME Water cooled e IM 240XWME Water cooled ...
Page 10: ...6 6 E1CG4880210 E1CG4880210 f IM 240XSME Remote Air cooled f IM 240XSME Remote Air cooled ...
Page 11: ...7 7 E1CG4880210 E1CG4880210 g IM 240AME Air cooled g IM 240AME Air cooled ...
Page 62: ...58 58 E1CG4880210 E1CG4880210 b IM 240DWME IM 240XWME b IM 240DWME IM 240XWME ...
Page 63: ...59 59 E1CG4880210 E1CG4880210 c IM 240DSME IM 240XSME c IM 240DSME IM 240XSME ...
Page 64: ...60 60 E1CG4880210 E1CG4880210 d IM 240AME d IM 240AME ...