26
2. WATER VALVE
1) Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the top panel and front panel.
4) Disconnect the inlet hose from the water valve.
5) Remove the mesh filter from the water valve.
6) Clean the mesh using a brush.
7) Replace the mesh and inlet hose in their correct positions.
8) Open the shut-off valve.
9) Plug in the icemaker or connect the power source.
10) Check for leaks.
11) Replace the panels in their correct positions.
Fig. 6
Coil
Do not remove
Filter
Packing
Inlet Hose