2. NO ERROR CODE INDICATION
Problem Check
Possible
Cause
Remedy
Icemaker will
not start.
Power source
Turned off.
Turn on.
Supply voltage too low.
Remove cause
Power failure
Wait until power is
resumed.
Transformer Defective.
Replace.
Power cord
Not connected properly.
Reconnect.
Open circuit (damaged).
Replace.
Controller board
Defective.
Replace.
Fuse
Blown out.
Check for cause.
Replace.
Bin control switch Stuck on other parts (e.g. ice
guide).
Remove ice.
Short circuit (display shows
“on”).
Replace.
Slab does not
break into
separate cubes.
Extension spring
Over-extended.
Replace.
Water plate
Obstacle caught between
evaporator and water plate.
Remove obstacle.
Icemaker will
not stop when
bin is filled with
ice.
Bin control switch
actuator
Out of position.
Place in position.
Broken. Replace.
Bin control switch Out of position.
Place in position.
Broken. Replace.
Bin control switch
detector
Out of position.
Place in position.
Broken. Replace.
Bin control micro
switch
Disconnected from switch box. Reconnect.
Seizing with open contacts.
Replace.
Controller board
Defective.
Replace.
Cloudy cubes.
Water quality
High hardness.
Set hard water control.
Switch to full drain flush
(see note below).
Ice condition
Slush ice.
Set slush ice control.
Abnormal noise Pump motor
Bearing worn out.
Replace.
Vapor lock.
Clean water valve filter.
Check water supply
cycle time setting.
Fan motor
Bearing worn out.
Replace.
Fan touching obstacle.
Remove obstacle.
Actuator motor
Gear worn out.
Replace.
Cubes drop
separately.
Refrigeration
circuit
Gas leaks (long defrost cycle). Repair.
Cam arm
Worn out.
Replace.
Note:
Full drain flush - After a freeze cycle ends, the unit drains all the remaining water in the tank and
refills the tank in the next freeze cycle.
Partial drain flush (default setting) - After a freeze cycle ends, the unit leaves the remaining water in
the tank and adds some water to fill the tank in the next freeze cycle.
Summary of Contents for IM-240ANE
Page 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a IM 240DNE Air cooled ...
Page 5: ...2 b IM 240DNE C Air cooled ...
Page 6: ...3 c IM 240DWNE Water cooled ...
Page 7: ...4 d IM 240DWNE C Water cooled ...
Page 8: ...5 e IM 240DWNE R452 Water cooled ...
Page 9: ...6 f IM 240ANE Air cooled ...
Page 10: ...7 g IM 240AWNE Water cooled ...
Page 11: ...8 h IM 240DSNE Remote Air cooled ...
Page 12: ...9 j URC 240C E 4 Condenser Unit ...
Page 20: ...17 a CONTROLLER BOARD LAYOUT Main Board Sub Board Combination ...
Page 37: ...34 2 WIRING DIAGRAM a IM 240DNE C XNE C IM 240DWNE C R452 XWNE C R452 IM 240ANE AWNE ...
Page 38: ...35 b IM 240DSNE XSNE URC 240C E 4 ...
Page 69: ...66 Fig 16 Controller Board Board Support Control Box Cover Screw ...