61
9. PUMP MOTOR
1) Unplug the icemaker or disconnect the power source.
2) Remove the top panel and front panel.
3) Disconnect the pump motor leads in the wiring channel.
4) Unscrew and remove the pump motor from the bracket.
5) Disconnect the pump suction and discharge tubings.
6) Install the new motor in the reverse order of the removal procedure.
7) Plug in the icemaker or connect the power source, and check for leaks.
8) Replace the panels in their correct positions.
10. WATER VALVE
1) Close the water supply tap.
2) Unplug the icemaker or disconnect the power source.
3) Remove the top panel and front panel.
4) Disconnect the receptacle (leads) from the water valve.
5) Remove the valve outlet tubing by releasing the clamp.
6) Remove the inlet hose and water valve.
7) Install the new valve in the reverse order of the removal procedure.
8) Open the water supply tap.
9) Plug in the icemaker or connect the power source.
10) Check for leaks.
11) Replace the panels in their correct positions.
Note: When replacing parts, disassemble as shown in Fig. 6 and replace the defective
parts.
Summary of Contents for IM-240ANE
Page 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a IM 240DNE Air cooled ...
Page 5: ...2 b IM 240DNE C Air cooled ...
Page 6: ...3 c IM 240DWNE Water cooled ...
Page 7: ...4 d IM 240DWNE C Water cooled ...
Page 8: ...5 e IM 240DWNE R452 Water cooled ...
Page 9: ...6 f IM 240ANE Air cooled ...
Page 10: ...7 g IM 240AWNE Water cooled ...
Page 11: ...8 h IM 240DSNE Remote Air cooled ...
Page 12: ...9 j URC 240C E 4 Condenser Unit ...
Page 20: ...17 a CONTROLLER BOARD LAYOUT Main Board Sub Board Combination ...
Page 37: ...34 2 WIRING DIAGRAM a IM 240DNE C XNE C IM 240DWNE C R452 XWNE C R452 IM 240ANE AWNE ...
Page 38: ...35 b IM 240DSNE XSNE URC 240C E 4 ...
Page 69: ...66 Fig 16 Controller Board Board Support Control Box Cover Screw ...