1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 4
Bin Drain Outlet
3/4” FPT
Icemaker Water
Supply Line
Drain Valve
Icemaker Drain
Outlet 3/4” FPT
Icemaker Water
Supply Inlet 1/2”
FPT
Icemaker Water
Supply Line
Shut-Off Valve
2-inch (5 cm)
air gap
Drain
Floor
Be sure there is sufficient
extra water supply line
and drain line for the
appliance to be pulled out
for service.
Separate piping to
approved drain. Leave a
2-inch (5-cm) vertical air
gap between the end of
each pipe and the drain.
13