background image

1. Icemaker

Icemaker Water 
Supply Inlet 

Minimum Icemaker 
Water Supply Line Size 

Icemaker Drain 
Outlet

Minimum Icemaker 
Drain Line Size

1/2" Female Pipe 
Thread (FPT)

1/4" Nominal ID 
Copper Water Tubing or 
Equivalent

3/4" Female Pipe 
Thread (FPT)

3/4" Nominal 
ID Hard Pipe or 
Equivalent

• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be 

pulled out for service.

 

 

Fig. 4

Bin Drain Outlet

3/4” FPT

Icemaker Water 

Supply Line 

Drain Valve

Icemaker Drain 

Outlet 3/4” FPT

Icemaker Water 

Supply Inlet 1/2” 

FPT

Icemaker Water 

Supply Line 

Shut-Off Valve

2-inch (5 cm) 

air gap

Drain

Floor

Be sure there is sufficient 
extra water supply line 
and drain line for the 
appliance to be pulled out 
for service.

Separate piping to 
approved drain. Leave a 
2-inch (5-cm) vertical air 
gap between the end of 
each pipe and the drain.

13

Summary of Contents for IM-500SAB

Page 1: ...Models IM 500SAB Modular Cuber Instruction Manual Issued 5 14 2019 hoshizakiamerica com ...

Page 2: ...er installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist qualified service technicians in the installation maintenance and service of the appliance Should the reader have any questions or concerns which have not been satisfactorily addressed please call sen...

Page 3: ...tion 4 I Specifications 6 A Electrical and Refrigerant Data 6 B Dimensions Connections 7 II Installation and Operating Instructions 8 A Location 8 B Checks Before Installation 9 C How to Remove Panels 9 D Setup 10 E Electrical Connection 11 F Water Supply and Drain Connections 12 G Final Checklist 14 H Startup 15 I Display 16 III Maintenance 17 A Maintenance Schedule 17 B Cleaning and Sanitizing I...

Page 4: ... accordance with applicable national state and local codes and regulations Electrical connection must be hard wired and must meet national state and local electrical code requirements Failure to meet these code requirements could result in death electric shock serious injury fire or damage The icemaker requires an independent power supply of proper capacity See the nameplate for electrical specifi...

Page 5: ...n and maintenance instructions carefully to reduce the risk of costly water damage In areas where water damage is a concern install in a contained area with a floor drain Install the icemaker in a location that stays above freezing Normal operating ambient temperature must be within 45 F to 100 F 7 C to 38 C Do not leave the icemaker on during extended periods of non use extended absences or in su...

Page 6: ... the right to make changes in specifications and design without prior notice 1 IM 500SAB Single Phase Model Number IM 500SAB AC Supply Voltage 115 60 1 Compressor 115V 10 2RLA 70 0LRA Pump 120V 0 55FLA 60W Fan 120V 0 50FLA 60W Actuator 115V 0 04FLA 10 5W Other 115 120V 0 16A Maximum Fuse Size 20 AMPS Max HACR Breaker USA Only 20 AMPS Max Circuit Breaker Canada Only 20 AMPS Minimum Circuit Ampacity...

Page 7: ...The storage bin opening must match the bottom opening as in the illustration B Dimensions Connections Unit mm inches 7 ...

Page 8: ...erature must be within 45 F to 100 F 7 C to 38 C Normal operating water temperature must be within 45 F to 90 F 7 C to 32 C Operation of the icemaker for extended periods outside of these normal temperature ranges may affect icemaker performance The icemaker will not work at sub freezing temperatures To prevent damage to the water supply line drain the icemaker if the air temperature is going to g...

Page 9: ...film from the panels If the appliance is exposed to the sun or to heat remove the film after the appliance cools Check that the refrigerant lines do not rub or touch lines or other surfaces and that the fan blade if applicable turns freely Check that the compressor is snug on all mounting pads The appliance can be installed on a storage bin 44 wide or wider The recommended storage bin is Hoshizaki...

Page 10: ...mage when installing the appliance See II B How to Remove Panels 5 Remove the protective plastic film from the panels If the unit is exposed to the sun or to heat remove the film after the unit cools NOTICE Do not use the side frame to lift the icemaker See Fig 1 Lift the icemaker from the base 6 Remove the package containing the accessories See Fig 1 7 Remove the shipping tape holding the bin con...

Page 11: ...ical connection must be hard wired and must meet national state and local electrical code requirements Failure to meet these code requirements could result in death electric shock serious injury fire or severe damage to equipment This unit requires an independent power supply See the nameplate for proper voltage and breaker fuse size Failure to use a proper breaker or fuse can result in a tripped ...

Page 12: ... ID copper water tubing or equivalent is required for the icemaker water supply line An icemaker water supply line shut off valve and drain valve must be installed Be sure there is sufficient extra water supply line for the unit to be pulled out for service Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG If the pressure exceeds 113 PSIG the use of a pressure reducing...

Page 13: ... Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service Fig 4 Bin Drain Outlet 3 4 FPT Icemaker Water Supply Line Drain Valve Icemaker Drain Outlet 3 4 FPT Icemaker Water Supply Inlet 1 2 FPT Icemaker Water Supply Line Shut Off Valve 2 inch 5 cm air gap Drain Floor Be sure there is sufficient extra water supply line and drain line for the ...

Page 14: ...pply voltage been checked or tested against the nameplate rating Has a proper ground been installed to the icemaker 7 Are the water supply and drain lines sized as specified Are the water supply line shut off valve s and drain valve s installed Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG 8 Is the compressor snug on all mounting pads Have the ...

Page 15: ...n the water supply line shut off valve s 2 Remove the front panel 3 Move the control switch to the ICE position 4 Replace the front panel in its correct position 5 Turn on the power supply and allow the icemaker to operate for a total of 10 minutes 6 Remove the front panel then move the service switch to the OFF position 7 Replace the front panel in its correct and allow the icemaker to drain for ...

Page 16: ...ode The unit will show an error code and safely stop if the unit is operating outside of acceptable parameters See the figure below If an error code appears please contact your local Hoshizaki Certified Service Representative for assistance E1 Abnormal freeze cycle E2 Abnormal harvest cycle EE Other 16 ...

Page 17: ...ation regulations Maintenance Schedule Frequency Area Task Daily Scoop Clean the ice scoop using a neutral cleaner Rinse thoroughly after cleaning Bi Weekly Air Filters Inspect Wash with warm water and neutral cleaner if dirty Monthly External Water Filters Check for proper pressure and change if necessary Icemaker Exterior Wipe down with a clean soft cloth Use a damp cloth containing a neutral cl...

Page 18: ...ply 3 Remove all ice from the storage bin 4 Remove the front panel 5 Remove the screw then move the water tank drain pipe to the drain position See Fig 5 Use the screw to secure the water tank drain pipe in the drain position 6 Make sure the control switch is in the ICE position then replace the front panel 7 Close the icemaker water supply line shut off valve 8 Turn on the power supply for 3 minu...

Page 19: ...pill the solution onto other parts 8 Replace the front panel and top panel in their correct positions 9 Turn on the power supply to start the sanitizing process 10 Turn off the power supply after 15 minutes 11 Open the icemaker water supply line shut off valve 12 Remove the front panel 13 Move the control switch to the ICE position 14 Replace the front panel 15 Turn on the power supply for 3 minut...

Page 20: ...he icemaker water supply line drain valve 4 Allow the line to drain by gravity 5 Attach compressed air or carbon dioxide supply to the icemaker water supply line drain valve 6 Move the control switch to the ICE position 7 Replace the front panel in its correct position then turn on the power supply 8 Blow the icemaker water supply line out using compressed air or carbon dioxide 2 Drain the water t...

Page 21: ...l The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service personnel 21 ...

Page 22: ...22 HOSHIZAKI AMERICA INC 618 Hwy 74 S Peachtree City GA 30269 USA TEL 770 487 2331 FAX 770 487 3360 www hoshizaki com 1A5483 010 ...

Reviews: