25
E. Control Board Information Display
1. With unit on, press and hold the "SERVICE 1" button for 3 seconds. Display changes to
"n1".
2. Use the "SERVICE 1" and "SERVICE 2" buttons to move through the list.
3. Press the "RESET" button to view the item’s value.
4. Press the "RESET" button to return to list.
5. Display returns to normal if no buttons are touched for 20 seconds.
Control Board Information Display
No. Item
Display (example)
–
n*, h*
n1
Freeze cycle time
count up (min)
21 min or 21%
100% (last 2 digits only)
n2 Freeze cycle
completion rate (%)
n3 Current evaporator
(cube control)
thermistor temp
-2°F (-19°C)
75°F (24°C)
n4 Current control
board thermistor
temp
n5 Water temp
(presumed)
Water temp 55°F (13°C) or more
Water temp less than 55°F (13°C)
n6 Current fan motor
rotation speed
If actual rotation speed is 1560 r/min The first two digits after actual
rotation speed is rounded to the
nearest 10.
n7 Current pump
motor rotation
speed
h1 Last freeze cycle
time (min)
21 min
h2 Number of freeze
cycles
If counted number of cycles is 162100
h3 Total number of
freeze cycles