5. ADJUSTMENT OF MICRO SWITCH

Actuator Motor Arm

To adjust the Micro Switch (A):

1) Close the Water Pan.

2) Push up the lever until the Micro Switch (A) trips with a click sound. Then, push the 

lever 1 mm further up to lock in position. Do not bend the actuator by pushing up the 

lever too much.

3) After adjustment, check for proper operation.

To adjust the Micro Switch (B):

1) Push the loosely fit Switch Bracket fully to the left.

2) Turn the Actuator Motor Arm to position the roller of the Micro Switch (B) as shown 

above.

3) Push the Switch Bracket fully to the right until the Micro Switch (B) trips with a click 

sound. Then, lock the Switch Bracket in that position.

4) After adjustment, check for proper operation.

Summary of Contents for IM-65LE-Q

Page 1: ...NO E1AH 806 ISSUED MAY 8 2010 REVISED HOSHIZAKI SELF CONTAINED CUBER MODEL IM 65LE Q SERVICE MANUAL ...

Page 2: ...GRAM 2 3 DIP SWITCH SETTING 3 4 SERVICE DIAGNOSIS 4 5 ADJUSTMENT OF MICRO SWITCH 5 This service manual provides specific information for IM 65LE Q only For any other information please refer to the service manual for the standard model IM 65LE i ...

Page 3: ...ating position ACM and CM stop State 4 When water plate releases ice WV closes and water plate starts to open further State 5 When water plate fully opens and S1 moves to left arm down position HV opens When 3 minutes passes after CM stops in state 2 CM restarts State 6 Cube control thermistor senses temperature higher than defrost setting water plate starts to close and water supply begins State ...

Page 4: ...2 2 WIRING DIAGRAM ...

Page 5: ...3 3 DIP SWITCH SETTING Dip Switch No Volume Setting Freeze VR DSW 1 A Defrost VR DSW 2 4 Dimple Range DSW 3 4 Water Supply DSW 4 0 Code Setting 1 DSW 5 9 Code Setting 2 DSW 6 7 ...

Page 6: ...model IM 65LE PROBLEM POSSIBLE CAUSE REMEDY 1 Deformed ice a Water Pan Lower Evaporator 1 Upper and Lower Evaporators not aligned 1 Readjust b Lower Evaporator 1 Coating damaged removed or worn 1 Replace 2 Cam Arm will not stop at a proper position a Micro Switch A 1 Open circuit or moisture inside 1 Replace b Micro Switch B 1 Open circuit or moisture inside 1 Replace ...

Page 7: ...tuator by pushing up the lever too much 3 After adjustment check for proper operation To adjust the Micro Switch B 1 Push the loosely fit Switch Bracket fully to the left 2 Turn the Actuator Motor Arm to position the roller of the Micro Switch B as shown above 3 Push the Switch Bracket fully to the right until the Micro Switch B trips with a click sound Then lock the Switch Bracket in that positio...