51
2) Install the new Relay in the reverse order of the removal procedure.
3) To prevent miswiring, check the terminal numbers and lead wire colors with the
Wiring Label.
[f] CONTROL BOARD TRANSFORMER
1) Disconnect the Connectors and Closed End Connectors connecting the Control
Board. (The Tie securing the harness may be removed. But be careful not to break
the lead wires.)
2) Remove the mounting screw and lift off the Transformer from the fit at the bottom.
3) Install the new Transformer in the reverse order of the removal procedure.
15. WATER TANK
1) Drain out the Water Tank by leaving the Control Switch in the “SERVICE” position
and the Service Switch in the “DRAIN” position for several tens of seconds.
2) Unplug the icemaker or disconnect the power source. Remove all ice from the
Storage Bin.
3) Disconnect the Overflow Pipe.
4) Remove the two Thumbscrews. Pull the Water Tank slightly toward you and push it
down. Be careful to avoid breakage when handling the parts. See Fig. 16.
5) Refit the Water Tank in the reverse order of the removal procedure.
6) Plug in the icemaker or connect the power source.
Fig. 16
Thumbscrew
Water Tank
Overflow Pipe