14
KM-1340MAH,
KM-1340MWH,
KM-1340MRH Sequence Flo
w Char
t and Component Operation
1.
One Min
ute
Fill Cyc
le
2.
Har
vest Cyc
le
3.
Freez
e Cyc
le
4.
Pump-Out
Cyc
le
Cyc
le Steps
WV
Energiz
ed
F/S
open
F/S
closed
Comp
energiz
ed
HGV
energiz
ed
FMR
energiz
ed
WV
contin
ues
Ther
mistor temp
reaches 48
°F (9°C)
(3.9 k
Ω
or less)
Har
vest timer star
ts
F/S
open
Comp
contin
ues
FMR
contin
ues
HGV
de-energiz
ed
WV
de-energiz
ed
PM
energiz
ed
FMS
energiz
ed
F/S
closed
Freez
e cycle
oper
ation tur
ned
ov
er to
F/S
Pump motor stops
for 2
sec.
and then
re
verses
for 10/20 sec.
each 1, 2, 5, or 10 cycles
.
Comp
contin
ues
FMR
contin
ues
HGV
energiz
ed
FMS
de-energiz
ed
F/S
Chec
k
F/S
Chec
k
•
Maxim
um
inlet
w
ater
v
alv
e
time:
6
min
utes
•
Maxim
um
har
vest
time:
20
min
utes
Ther
mistor in
control
1 to 3 min
ute timer
in control
•
Minim
um
freez
e
time:
5
min
utes
•
Maxim
um
freez
e
time:
freez
e
timer
setting
5 min
ute timer
in control
F/S
in
control
Initial star
tup alw
ays
begins here
"E" board will ha
ve
5
second dela
y
If
F/S
is open, compressor stops and cycle retur
ns to 1 min
ute fill
Leg
end:
Comp
- compressor
FMS
- self-contained f
an motor
HGV
- hot gas v
alv
e
WV
- inlet w
ater v
alv
e
FMR
- remote f
an motor
F/S
- float s
witch
PM
- pump motor
Summary of Contents for KM-1340MAH
Page 8: ...8 B Condensing Unit 1 URC 14F ...
Page 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Page 11: ...11 2 KM 1340MWH water cooled ...
Page 12: ...12 3 KM 1340MRH remote air cooled ...
Page 24: ...24 2 KM 1340MWH water cooled ...
Page 25: ...25 3 KM 1340MRH remote air cooled ...
Page 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...