CONTENTS
I. Specifications ...................................................................................................................... 5
A. Icemaker ....................................................................................................................... 5
1. KM-1340MAH (air-cooled) ....................................................................................... 5
2. KM-1340MWH (water-cooled) ................................................................................. 6
3. KM-1340MRH (remote air-cooled) .......................................................................... 7
B. Condensing Unit ............................................................................................................ 8
1. URC-14F ................................................................................................................. 8
II. General Information ......................................................................................................... 10
A. Construction ................................................................................................................ 10
1. KM-1340MAH (air-cooled) ..................................................................................... 10
2. KM-1340MWH (water-cooled) ............................................................................... 11
3. KM-1340MRH (remote air-cooled) ........................................................................ 12
B. Sequence of Operation ............................................................................................... 13
1. One Minute Fill Cycle ............................................................................................ 13
2. Initial Harvest Cycle .............................................................................................. 13
3. Freeze Cycle ......................................................................................................... 13
4. Pump-Out Cycle ................................................................................................... 13
5. Normal Harvest Cycle .......................................................................................... 13
C. Control Board .............................................................................................................. 15
1. Control Board Layout ............................................................................................. 16
2. Features ................................................................................................................ 17
a) Maximum Water Supply Period – 6 minutes ....................................................... 17
b) Harvest Backup Timer and Freeze Timer ........................................................... 17
c) High Temperature Safety .................................................................................... 17
d) Low Water Safety ............................................................................................... 17
e) High Voltage and Low Voltage Cut-outs ............................................................. 17
f) LED Lights and Audible Alarm Safeties ............................................................... 18
3. Controls and Adjustments ..................................................................................... 19
a) Default Dip Switch Settings ................................................................................ 19
b) Harvest Control – Thermistor ............................................................................. 19
c) Harvest Timer (dip switch 1 & 2) ......................................................................... 20
d) Pump-Out Timer (dip switch 3 & 4)..................................................................... 20
e) Pump-Out Frequency Control (dip switch 5 & 6) ................................................ 21
f) Freeze Timer (dip switch 9 & 10) ......................................................................... 21
g) Bin Control .......................................................................................................... 21
4. Control Board Check Procedure ............................................................................ 22
5. Control Board Replacement .................................................................................. 22
Summary of Contents for KM-1340MAH
Page 8: ...8 B Condensing Unit 1 URC 14F ...
Page 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Page 11: ...11 2 KM 1340MWH water cooled ...
Page 12: ...12 3 KM 1340MRH remote air cooled ...
Page 24: ...24 2 KM 1340MWH water cooled ...
Page 25: ...25 3 KM 1340MRH remote air cooled ...
Page 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...