36
Problem
Possible Cause
Remedy
m)Interlock Switch Open
(Cleaning Valve)
1. Misaligned.
1. Realign.
2. Bad contacts.
2. Check for continuity and
replace.
n)Wash Switch
1. WASH position.
1. Move to ICE position.
2. Bad contacts.
2. Check and replace.
[2] Water continues to
be supplied, and the
icemaker will not
start.
a)Float Switch
1. Connector
disconnected.
1. Place in position.
2. Leads opened or
defective switch.
2. Check and replace.
3. Float does not move
freely.
3. Clean or replace.
b)Control Board
1. Defective.
1. Replace.
[3] Compressor will
not start or stops
operating.
a)Magnetic Contactor
1. Bad contacts.
1. Check for continuity and
replace.
2. Coil winding opened. 2. Replace.
b)Start Capacitor or Run
Capacitor
1. Defective.
1. Replace.
c) Internal Overload
Protector Open (check
1 through 3 to the right
and d through f below)
1. Loose terminal.
1. Tighten or replace.
2. Voltage.
2. Check and correct.
3. Dirty condenser.
3. Clean.
d)Starter
1. Bad contacts.
1. Check and replace.
2. Coil winding opened. 2. Replace.
e)Compressor
1. Wiring to compressor. 1. Check for loose
connection or open, and
replace.
2. Defective.
2. Replace.
3. Protector tripped.
3. Reduce temperature.
f) Control Board
1. No power to contactor. 1. See "II.C.4. Control Board
Check Procedure."
[4] Water continues to
be supplied in freeze
cycle.
a)Inlet Water Valve
1. Diaphragm does not
close.
1. Check for water leaks with
icemaker off.
b)Control Board
1. Defective.
1. See "II.C.4. Control Board
Check Procedure."
[5] No water comes from
spray tubes. Water
pump will not start, or
freeze cycle time is
too short.
a)Water Supply Line
1. Water pressure too
low and water level in
water tank too low.
1. Check and get
recommended pressure.
b)Inlet Water Valve
1. Dirty mesh filter or
orifice and water level
in water tank too low.
1. Clean.
c) Water System
1. Water leaks.
1. Check connections for
water leaks, and replace.
Summary of Contents for KM-1340MAH
Page 8: ...8 B Condensing Unit 1 URC 14F ...
Page 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Page 11: ...11 2 KM 1340MWH water cooled ...
Page 12: ...12 3 KM 1340MRH remote air cooled ...
Page 24: ...24 2 KM 1340MWH water cooled ...
Page 25: ...25 3 KM 1340MRH remote air cooled ...
Page 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...