52
1. Cleaning Procedure
1) Dilute approximately 27 fl. oz. (800 ml) of Hoshizaki "Scale Away" with 5 gallons (19 l)
of warm water.
2) Remove all ice from the evaporator and the storage bin.
Note: To remove cubes on the evaporator, turn off the power supply and turn it on
after 3 minutes. The defrost cycle starts and the cubes will be removed from the
evaporator.
3) Turn off the power supply.
4) Remove the front panel and then remove
the insulation panel by first lifting the top
panel and sliding the top panel to the back
a little.
5) Remove the rubber cap covering
the overflow pipe in the water tank.
Remove the overflow pipe by turning it
counterclockwise. Drain the water tank.
See Fig. 4.
6) Replace the overflow pipe and the rubber cap in their correct positions.
7) In bad or severe water conditions, clean the float switch assembly as described below.
Otherwise, continue to step 8.
a. Remove the float switch assembly from the mounting bracket and remove the
rubber boot from the bottom of the assembly.
b. Remove the retainer rod from the bottom of the float switch assembly, then remove
the float. Be careful not to bend the retainer rod excessively when removing it.
c. Wipe down the float switch assembly's housing, shaft, float, and retainer rod with
cleaning solution. Wipe the inside of the rubber boot with cleaning solution.
d. Reassemble the float switch assembly and replace it and the rubber boot in their
correct positions.
8) Pour the cleaning solution into the water tank.
9) Fully open the cleaning valve on the left side wall of the machine compartment.
10) Move the control switch on the control box to the "WASH" position.
11) Replace the insulation panel and the front panel in their correct positions.
Note: When replacing the insulation panel, do not catch the hose between the panel
and the body.
12) Turn on the power supply, and start the washing process.
13) Turn off the power supply after 30 minutes.
14) Remove the front panel, and then remove the insulation panel by first lifting the top
panel and sliding the top panel to the back a little.
15) Remove the rubber cap covering the overflow pipe in the water tank. Remove the
overflow pipe by turning it counterclockwise. Drain the water tank. Replace the overflow
pipe, the rubber cap and the insulation panel in their correct positions.
Rubber Cap
Overflow Pipe
Fig. 4
Summary of Contents for KM-1340MAH
Page 8: ...8 B Condensing Unit 1 URC 14F ...
Page 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Page 11: ...11 2 KM 1340MWH water cooled ...
Page 12: ...12 3 KM 1340MRH remote air cooled ...
Page 24: ...24 2 KM 1340MWH water cooled ...
Page 25: ...25 3 KM 1340MRH remote air cooled ...
Page 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...