55
3) Wait 3 minutes.
4) Move the control switch to the "ICE" position.
5) Allow 5 minutes for the icemaker to fill with water and the water pump to start operating.
6) Close the water-cooled condenser water supply line shut-off valve.
7) Open the drain valve for the water-cooled condenser water supply line.
8) Allow the line to drain by gravity.
9) Attach compressed air or carbon dioxide supply to the condenser water line drain valve.
10) Blow the water-cooled condenser out using compressed air or carbon dioxide until
water stops coming out.
2. Remove the water from the potable water supply line:
1) Remove the front panel, if not already removed.
2) Move the control switch on the control box to the "OFF" position.
3) Wait 3 minutes.
4) Close the potable water supply line shut-off valve and open the potable water supply
line drain valve.
5) Allow the line to drain by gravity.
6) Attach compressed air or carbon dioxide supply to the potable water supply line drain
valve.
7) Move the control switch to the "ICE" position.
8) Blow the potable water line out using compressed air or carbon dioxide.
3. Drain the potable water tank:
1) Turn off the power supply.
2) Move the control switch to the "OFF" position.
3) Remove the insulation panel.
4) Remove the rubber cap covering
the overflow pipe in the water tank.
Remove the overflow pipe by turning it
counterclockwise. Drain the water tank.
See Fig. 5.
5) Replace the overflow pipe, the rubber cap and the insulation panel in their correct
positions.
6) Remove all ice from the storage bin, and clean the storage bin.
7) Replace the front panel in its correct position.
8) Close the drain valve(s).
Rubber Cap
Overflow Pipe
Fig. 5
Summary of Contents for KM-1340MAH
Page 8: ...8 B Condensing Unit 1 URC 14F ...
Page 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Page 11: ...11 2 KM 1340MWH water cooled ...
Page 12: ...12 3 KM 1340MRH remote air cooled ...
Page 24: ...24 2 KM 1340MWH water cooled ...
Page 25: ...25 3 KM 1340MRH remote air cooled ...
Page 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...