64
6. KM-515MWH
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
9.6 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
960(5.14)
920(4.8)
WATER gal./24HR (gal./100 lbs.)
103(23.0)
180(39.0)
WATER COOLED CONDENSER
473(106)
263(57)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
10. lbs. (4.5 kg) 480pcs.
BIN CONTROL SYSTEM
Thermostat or Mechanical Bin Control
REFRIGERANT CHARGE
R404A, 0 lb. 14.8 oz. (420g)
Performance Data
70/21
462
210
457
207
427
194
80/27
458
208
451
205
407
185
90/32
457
207
446
202
407
185
lbs./day kg./day
100/38
443
201
437
198
371
168
70/21
80/27
90/32
watts
100/38
70/21
444
1.68
482
1.83
727
2.75
80/27
473
1.79
533
2.02
884
3.35
90/32
482
1.83
575
2.18
887
3.36
gal./day m3/day
100/38
622
2.35
648
2.45
1173
4.44
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
266
18.7
267
18.8
270
19.0
80/27
267
18.7
268
18.8
272
19.1
90/32
267
18.8
269
18.9
273
19.2
PSIG kg/cm2G
100/38
268
18.8
270
19.0
276
19.4
70/21
48
3.4
50
3.5
55
3.9
80/27
49
3.5
52
3.7
59
4.1
90/32
50
3.5
54
3.8
60
4.2
PSIG kg/cm2G
100/38
52
3.6
55
3.9
66
4.6
8,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
45 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT
TEMP. (ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
920
932
932
929
947
938
932
960
955
926
959
950
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
28
29
31
28
30
32
29
31
33
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.6
4.0
3.9
4.2
3.4
3.5
4.0
2.8
2.8
3.5
2.8
2.8
HEAD PRESSURE
SUCTION PRESSURE
29
31
35
ENG.F-011.1.0205