73
15. KM-901MRH3 with URC-9F
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
7.0A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1830(5.4)
1670(4.5)
WATER gal./24HR (gal./100 lbs.)
147(18.0)
254(28.2)
ICE PRODUCTION PER CYCLE
14.2 lbs. (6.4 kg) 720pcs.
BIN CONTROL SYSTEM
Thermostat or Mechanical Bin Control
TOTAL REFRIGERANT CHARGE
R404A, 9 lbs. 4 oz. (4200g)
REFRIGERANT CHARGE BY UNIT
Icemaker 5 lbs. 5 oz. Cond. Unit 3 lbs. 15 oz.
Performance Data
70/21
899
408
874
397
817
371
80/27
880
399
842
382
772
350
90/32
874
397
815
370
749
340
lbs./day kg./day
100/38
855
388
800
363
689
313
70/21
80/27
90/32
watts
100/38
70/21
254
0.96
222
0.84
203
0.77
80/27
230
0.87
181
0.69
174
0.66
90/32
222
0.84
147
0.56
134
0.51
gal./day m3/day
100/38
185
0.70
144
0.54
123
0.46
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
206
14.5
225
15.8
248
17.5
80/27
220
15.5
249
17.5
272
19.1
90/32
225
15.8
270
19.0
293
20.6
PSIG kg/cm2G
100/38
229
16.1
275
19.4
315
22.1
70/21
36
2.5
38
2.7
41
2.9
80/27
37
2.6
40
2.8
44
3.1
90/32
38
2.7
42
3.0
46
3.2
PSIG kg/cm2G
100/38
39
2.7
43
3.0
49
3.4
14,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
121 CU. IN (URC-9F)
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3.4
2.7
2.4
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.4
3.9
3.6
4.0
3.3
3.2
3.9
2.8
2.6
23
20
22
24
20
23
26
1716
1837
1890
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
19
20
21
20
21
APPROXIMATE ELECTRIC
CONSUMPTION
1670
1717
1755
1706
1779
1803
1717
1830
1861
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205