6
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KM-340M_J
Single Phase
Model Number
KM-340MAJ
KM-340MWJ
AC Supply Voltage
115/60/1
115/60/1
Compressor
115V 7.4FLA 42LRA
115V 6.7RLA 42LRA
Pump
120V 0.5FLA 10W
120V 0.5FLA 10W
Fan
120V 1.0FLA 1/15H
--- --- ---
Other
115V 0.15A
115V 0.15A
Maximum Fuse Size 20 AMPS
20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
Design Pressure
HI-467PSI LO-210PSI
HI-427PSI LO-210PSI
Refrigerant
404a 1 LB. 4.8 OZ.
404a 1 LB. 0.9 OZ
2. KM-515M_J
Single Phase
Model Number
KM-515MAJ
KM-515WJ
KM-515MRJ
AC Supply Voltage
115-120/60/1
115-120/60/1
115-120/60/1
Compressor
115V 9.0RLA 54.5LRA
115V 8.3 RLA
54.5LRA
115V 8.3RLA
54.5LRA
Pump
120V 0.5FLA 10W
120V 0.5FLA 10W
120V 0.5FLA 10W
Fan
120V 1.0FLA 1/15HP
--- --- ---
120V 3A MAX (Fan in URC)
Other
115-120V 0.15A
115-120V 0.15A
115-120V 0.9A
Maximum Fuse Size 20 AMPS
20 AMPS
20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
20 AMPS
Design Pressure
HI - 467PSI LO - 250PSI
HI - 467PSI LO - 250PSI
HI - 467PSI LO - 250PSI
Refrigerant
404a 1 LB 7.6 OZ
404a 15.2 OZ
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser