24
a)
Bin Full Diagnosis
: Place an object 5" to 7" (127 to 178 mm) away from the BC
sensor lens. If shut down cycle does not start, confirm BC controller green "LED 1"
LED turns off. If not, check for 4VDC at CB K4 pin #1 (R) to CB K4 pin #2 (BK).
If 1VDC is present, confirm object placement. If object placement is correct, replace
BC sensor and BC controller. If BC controller green "LED 1" LED turns off and CB
yellow "BC OPEN/CLOSED" LED does not turn on and 4VDC is present at CB K4
pin #1 (R) to CB K4 pin #2 (BK), replace CB. If CB yellow "BC OPEN/CLOSED" LED
turns on and shut down cycle does not start, see "II.B.1.4) 1-min. Fill Cycle."
Control Board K4 Bin Control Connector
Bin Full (open)
Pin #
Wire Color
VDC
#1 to #2
R to BK
4VDC
#1 to #3
R to W
1VDC
#2 to #3
BK to W
5VDC
C
ALP
X1
X4
X3
X2
BC OPEN
BC CL
OSED
1
2
3
4
5
6
7
8
910
ON
1 2 3 4 5
ON
S4
1
S3
ALARM RESET
OUTPUT TEST
K7
K6
K3
K4
K5
K1
K2
S5
POWER OK
LED 2
LED 3
LED 4
LED 1
P/N 2A3792-01
BLA
CK
RED
WHITE
10 9 8 7 6 5 4 3 2 1
S2
1
3
3
2
2
1
3
2
1
3
2
CB
Bin Control
6) Once the icemaker restarts, move the control switch to the "OFF" position, then turn off
the power supply.
7) Replace the base cover and right side panel in their correct positions.
8) Move the control switch to the "ON" position. Replace the front panel in its correct
position, then turn on the power supply to start the automatic icemaking process.
Legend:
BC
–bin control;
CB
–control board;
CT
–control transformer
Summary of Contents for KM-350MAJ