55
4. KM-520MWJ
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
8.45 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
860 (4.65)
880 (4.45)
WATER gal./24HR (gal./100 lbs.)
66 (14.8)
114 (24.1)
WATER COOLED CONDENSER
333 (75)
149 (31)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
10.7 lbs. (4.8 kg) 480pcs.
BIN CONTROL SYSTEM
Ultra-Sonic Sensor
REFRIGERANT CHARGE
R404A, 0 lb. 12.7 oz. (360g)
Performance Data Sheet
70/21
474
215
465
211
451
204
80/27
467
212
454
206
438
199
90/32
465
211
444
201
428
194
lbs./day kg./day
100/38
462
209
440
200
414
188
70/21
80/27
90/32
watts
100/38
70/21
263
1.00
303
1.15
376
1.42
80/27
294
1.11
355
1.34
438
1.66
90/32
303
1.15
399
1.51
479
1.81
gal./day m
3
/day
100/38
371
1.40
418
1.58
552
2.09
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
284
20.0
284
19.9
282
19.8
80/27
284
20.0
283
19.9
280
19.7
90/32
284
19.9
283
19.9
280
19.7
PSIG kg/cm
2
G
100/38
283
19.9
282
19.9
278
19.5
70/21
54
3.8
54
3.8
55
3.9
80/27
54
3.8
55
3.8
56
3.9
90/32
54
3.8
55
3.9
56
3.9
PSIG kg/cm
2
G
100/38
55
3.8
55
3.9
57
4.0
6,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
20 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
2.0
2.0
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
2.5
HARVEST CYCLE TIME
3.1
2.8
2.7
2.9
2.4
2.5
2.8
2.0
2.0
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
30
30
31
30
31
32
30
32
33
APPROXIMATE ELECTRIC
CONSUMPTION
880
874
864
876
866
856
874
860
850
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
33
858
840
30
32
872
ENG.F-011.1.0205
Summary of Contents for KM-350MAJ