56
5. KM-520MRJ with URC-5F
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
12.05 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
990 (4.80)
920 (4.05)
WATER gal./24HR (gal./100 lbs.)
67 (13.6)
173 (31.6)
ICE PRODUCTION PER CYCLE
10.6 lbs. (4.8 kg) 480pcs.
BIN CONTROL SYSTEM
Ultra-Sonic Sensor
REFRIGERANT CHARGE
TOTAL R404A, 4 lb. 2.7 oz. (1890g)
ICEMAKER, 2 lb. 4.7 oz. (1040g)
CONDENSER, 1 lb. 14 oz. (850g)
Performance Data Sheet
70/21
547
248
532
241
507
230
80/27
535
243
512
232
484
220
90/32
532
241
495
225
468
212
lbs./day kg./day
100/38
525
238
489
222
444
201
70/21
80/27
90/32
watts
100/38
70/21
173
0.65
142
0.54
129
0.49
80/27
149
0.57
101
0.38
105
0.40
90/32
142
0.54
67
0.25
64
0.24
gal./day m
3
/day
100/38
108
0.41
66
0.25
60
0.23
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
207
14.6
223
15.6
249
17.5
80/27
219
15.4
243
17.1
272
19.1
90/32
223
15.6
260
18.3
289
20.3
PSIG kg/cm
2
G
100/38
230
16.1
267
18.8
315
22.1
70/21
50
3.5
50
3.5
53
3.7
80/27
50
3.5
51
3.6
55
3.9
90/32
50
3.5
51
3.6
55
3.8
PSIG kg/cm
2
G
100/38
52
3.6
52
3.6
58
4.1
6,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
43 CU. IN.
URC-5F
34
APPROXIMATE ELECTRIC
CONSUMPTION
920
941
963
936
968
986
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
941
990
1011
943
995
1030
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
25
26
28
26
28
30
26
29
32
26
30
HARVEST CYCLE TIME
3.4
3.0
2.9
3.1
2.5
2.6
3.0
2.0
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER
2.6
2.0
2.0
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205
Summary of Contents for KM-350MAJ