37
4. PERFORMANCE DATA
[a] KM-500MAH
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for
reference only.
We reserve the right to make changes in specifications and design without prior notice.
70/21
499
226
468
212
428
194
80/27
475
216
427
194
389
176
90/32
468
212
393
178
353
160
lbs./day kg./day
100/38
461
209
384
174
317
144
70/21
80/27
90/32
watts
100/38
70/21
250
0.95
210
0.79
187
0.71
80/27
219
0.83
157
0.59
153
0.58
90/32
210
0.79
113
0.43
100
0.38
gal./day m
3
/day
100/38
163
0.62
110
0.42
89
0.34
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
244
17.2
263
18.5
285
20.1
80/27
259
18.2
289
20.3
308
21.7
90/32
263
18.5
310
21.8
331
23.3
PSIG kg/cm
2
G
100/38
266
18.7
315
22.1
350
24.6
70/21
49
3.4
52
3.7
54
3.8
80/27
51
3.6
56
3.9
57
4.0
90/32
52
3.7
59
4.1
61
4.3
PSIG kg/cm
2
G
100/38
52
3.6
59
4.2
62
4.4
3.3
2.6
2.0
8206 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
3.3
2.0
27
28
29
31
33
37
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
1164
1175
1178
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
1186
1178
1197
1212
1219
1204
1227
1241
1268
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
35
29
30
33
HARVEST CYCLE TIME
HEAD PRESSURE
2.0
3.9
38
43
3.5
3.3
3.1
2.5
2.0
Summary of Contents for KM-500MAH
Page 28: ...28 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 500MAH ...
Page 29: ...29 b KM 500MWH ...
Page 30: ...30 c KM 500MRH ...
Page 34: ...34 b KM 500MRH with auxiliary codes M 2 and after ...
Page 35: ...35 3 TIMING CHART ...
Page 36: ...36 ...