3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.
a) Default S4 Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-600MAH
OFF OFF OFF OFF ON ON OFF OFF OFF OFF
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Do Not Adjust
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Normally off (7 & 8)
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reaches 48°F (9°C) at the
evaporator outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest
timer is factory-adjusted, and no adjustment is required. However, a setting longer than
the factory setting may be advised in cases where the flush provided at harvest needs
to be prolonged for extra cleaning. Before changing this setting, contact Hoshizaki
Technical Support at 1-800-233-1940 for recommendations. Keep in mind that setting
the harvest timer to a longer setting will decrease 24 hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump out
S4 Dip Switch Setting
Time
(seconds)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180