15
c) Pump-Out Timer (S4 dip switch 3 & 4)
When a freeze cycle is completed, the pump motor stops, and the icemaker resumes
operation in 2 seconds. Then, during cycles when a pump out is called for, the pump
motor drains the water tank for the time determined by the pump-out timer. The
pump-out timer also acts in place of the harvest timer during cycles with a pump out.
The pump-out timer is factory-adjusted, and no adjustment is required.
S4 Dip Switch Setting
Time (seconds)
Inlet Water
Valve
No. 3
No. 4
T1
T2
OFF
OFF
10
150
Closed
ON
OFF
10
180
Closed
OFF
ON
10
120
Open
ON
ON
20
180
Closed
T1: Time to drain the water tank
T2: Harvest timer at pump out
Pump out always occurs after the 1st freeze cycle. Then, depending on the
pump-out frequency control setting (dip switch 5 & 6), pump out occurs every cycle, or
every 2nd, 5th, or 10th cycle.
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump motor drains the water tank at the frequency set by the pump-out frequency
control.
The pump-out frequency control is factory-adjusted to drain the water tank every
10 cycles, and no adjustment is generally required. However, where water quality is
bad and the icemaker needs a pump out more often, the pump-out frequency can be
adjusted as shown in the table below.
S4 Dip Switch Setting
Frequency
No. 5
No. 6
OFF
OFF
every cycle
ON
OFF
every 2 cycles
OFF
ON
every 5 cycles
ON
ON
every 10 cycles
e) Factory Use (S4 dip switch 7 & 8)
Factory set for optimum performance. Do not adjust.