28
2. Evaporator is Frozen Up
Problem
Possible Cause
Remedy
[1]Freeze cycle time is
too long.
a)Float Switch
1. Leads short-circuit or
defective switch.
1. Check and replace.
2. Float does not move
freely.
2. Clean or replace.
b)Inlet Water Valve
1. Diaphragm does not
close.
1. Check for water leaks with
icemaker off.
c) Control Board
1. Defective.
1. See "II.C.4. Control Board
Check Procedure."
d)Water Pump
1. RPM too slow.
1. Check and replace.
e)Spray Tubes
1. Clogged.
1. Unclog.
f) Evaporator
1. Scaled up.
1. Clean.
g)Expansion Valve
1. Operating erratically.
1. Check and replace.
[2]All ice formed on
evaporator does not
fall into bin in harvest
cycle.
a)Evaporator
1. Scaled up.
1. Clean.
b)Water Supply Line
1. Water pressure too
low.
1. Check and get
recommended pressure.
c) Water Filter System
1. Dirty/Restricted.
1. Replace filter.
d)Inlet Water Valve
1. Dirty mesh filter or
orifice.
1. Clean.
2. Diaphragm does not
close.
2. Check for water leaks with
icemaker off.
e) Ambient and/or water
temperature.
1. Too cool.
1. Increase temperature.
f) Thermistor
1. Out of position or
loose attachment.
1. See "V.I. Removal
and Replacement of
Thermistor."
g)Control Board
1. Harvest timer is set
too short.
1. Adjust longer, referring
to "II.C.3. Controls and
Adjustments, b) Harvest
Timer."
2. Defective.
2. See "II.C.4. Control Board
Check Procedure."
[3]Other.
a)Spray Tubes
1. Clogged.
1. Clean.
2. Out of position.
2. Place in position.
b)Water System
1. Dirty.
1. Clean.
2. Water supply line too
small; requires 3/8"
OD line dedicated per
machine.
2. Increase water line size.
3. Water filter flow rate
too small.
3. Replace with filter that has
larger flow rate.
c) Refrigerant
1. Low charge.
1. Check for leaks and
recharge.
d)Expansion Valve
1. Bulb out of position or
loose attachment.
1. Place in position.
2. Defective.
2. Replace.