22
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 12
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker Water Supply
Line Shut-Off Valve
Icemaker Water Supply
Line Drain Valve
Icemaker Drain
Outlet 3/4" FPT
Icemaker Condensation
Drain Outlet
3/8" OD Hard Tube
Bin Drain Outlet
3/4" FPT
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the drain.
2-inch
(5-cm)
air gap
Floor
Drain
Ice
Storage
Bin
Icemaker
Vent Tube
Minimum 1/4" Nominal ID
Copper Water Tubing
Minimum 3/4" Nominal ID Hard Pipe
Vent Tube