29
[c] DISPLAY MODE
No
Item
Display (example)
–
n*, h*
n1
Freeze cycle time count
up (min)
21 min or 21%
100% (last 2 digits only)
n2
Freeze cycle completion
rate (%)
n3
Current cube control
thermistor temp
-19°C
24°C
n4
Current ambient
thermistor temp
n5
Water temp (presumed)
Water temp 13°C or more
Water temp less than 13°C
n6
Current condenser
thermistor temp
Same as n3 and n4
h1
Last freeze cycle time
(min)
21 min
h2
Number of freeze cycles
If counted number of cycles is 162100
h3
Total number of freeze
cycles
h4
Error log
If 3 errors from latest to oldest are E4, E3, and E1
h5
Software version
Ver. 1.0A is displayed as follows alternately for 1 sec ON and
0.5 sec OFF
h6
Default model code
Set model codes from “00” to “FF” (hexadecimal, 256 patterns)