30
5. ERROR CODES
[a] ERROR CODES, CAUTION CODES
* When the controller board detects an error, the display shows one of the following
errors, caution and alarm codes in the display mode. Operation depends on the type of
error.
* The error and caution codes other than E1 and E2 are indicated as “EE” or “EF” in the
7-segment display at the time of occurrence. The error log is indicated up to five errors
from the latest entry.
Error
Item
Description
Operation
Reset
E1
Freeze error
Freeze backup timer (60 minutes after
water pan starts to close) counts up before
freeze cycle completes, and evaporator
temperature is 0°C or higher.
Shut down
Press reset
switch
E2
Defrost error
Defrost backup timer (30 minutes after
water pan starts to open) counts up before
defrost cycle completes.
Shut down
Press reset
switch
E3
Water pan
opening
error
Water pan has not fully opened within 60
seconds, and 3 minutes have passed even
with opening failure control.
Halt
Press reset
switch
Unit resumes operation after 60 minutes
and repeats the above error.
Shut down
E4
Water pan
closing error
Water pan has not fully closed within 50
seconds, opened and started to close
again, but failed to close fully within 50
seconds.
Halt
Press reset
switch
Unit resumes operation after 60 minutes
and repeats the above error.
Shut down
E5
High
temperature
error
Evaporator temperature stays 60°C or
higher for 5 seconds or more.
Shut down
Press reset
switch
E9
Condenser
thermistor
error
Condenser thermistor circuit is open or
shorted for 2 seconds.
Shut down
Replace
thermistor
EA
Data error
Model setting data memory IC is defective.
Shut down
Replace
controller board
EC
Cube control
thermistor
error
Cube control thermistor circuit is open or
shorted for 2 seconds.
Shut down
Replace
thermistor
Ed
Water
regulator
error
Cooling water cannot stop by water
regulator error, and thermistor senses set
point or lower temperature.
Continue
Press reset
switch