[b] SERVICE DIAGNOSIS
Error
Check
Possible Cause
Remedy
E1
Water valve
Closing failure
Clean or replace
Refrigeration circuit
Gas leak
Repair
Clogged capillary
Replace heat exchanger
Clogged expansion valve
Replace
Compressor
Defective
Replace
Starting failure
Check supply voltage or replace
electrical components
Compressor relay
Coil circuit open
Replace
Condenser
Clogged
Clean
Fan motor
Locked
Replace
Low RPM
Replace
Broken fan
Replace fan
Hot gas valve
Closing failure
Replace
Cube control thermistor
Disconnected
Reconnect
E2
Hot gas valve
Opening failure
Replace
Controller board
Defective
Replace
E3
Actuator motor
Defective
Replace
Controller board
Relay contact failure
Replace
Defective
Replace
E4
Actuator motor
Defective
Replace
Controller board
Relay contact failure
Replace
Defective
Replace
E5
Hot gas valve
Closing failure
Replace
Controller board
Relay contact failure
Replace
E9
Condenser thermistor
Open or short circuit
Replace
Controller board
Connector disconnected
Reconnect
EA
Controller board
Defective
Replace
EC
Cube control thermistor
Open or short circuit
Replace
Controller board
Connector disconnected
Reconnect
Ed
Water regulator
Clogged with foreign matter
Unclog
Corroded spring
Replace